Installation; Damper Stop Installation - MHSC VWFOD24 Installation And Operating Instructions Manual

Vented outdoor natural gas or propane/lpg log set, control type: manual match light
Table of Contents

Advertisement

VWFOD Vented Outdoor Gas Log Set
INSTALL AND OPERATE THE APPLIANCE
AS DIRECTED IN THIS MANUAL.

DAMPER STOP INSTALLATION

A damper stop must be provided with the unit. The damper
stop must be installed as shown in Figure 3 to prevent
full closure of the fireplace damper blade and provide a
minimum flue opening, per table on page 5.
Should the clamp not fit, or provide the required permanent
opening from the table, have the damper cut to provide
a minimum permanent opening or install a permanent
stop.
FOR MASSACHUSETTS RESIDENTS ONLY
Installation of this vented gas log set in the Commonwealth
of Massachusetts requires the damper be permanently
removed or welded in the fully open position. In addition, a
naturally vented gas log may not be installed in a bedroom
or bathroom in the Commonwealth of Massachusetts.
FP2370
Figure 3 -
FP2370
Damper Stop Installation
damper
6
Damper Stop
Damper
BEFORE INSTALLING THE APPLIANCE:
Turn off gas supply to fireplace or firebox.
Clean the fireplace floor and chimney before install-
ing the log set. Seal any ash clean-out doors to
protect the unit from down drafts.
ASSEMBLY PROCEDURE
1. Place grate/burner assembly into firebox with the
f
ront pan facing forward.
2. Drill two (2) 5/32" diameter holes approximately 1Z\x"
deep.
3. Anchor the front pan to the floor using the screws pro-
vided.
Proper installation of the grate is essential to prevent
any movement of the gas logs and controls during
operation.
Screws
Figure 4 -
Secure Grate/Burner Assembly into Firebox
FP2643
secure grate

INSTALLATION

FP2643
20300546

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vwfod30

Table of Contents