Technical Data - GE APN08 Series Technical Service Manual

Portable room air conditioner
Hide thumbs Also See for APN08 Series:
Table of Contents

Advertisement

DIS C ONNE C T P OWE R B E F OR E S E R V IC ING
IMP OR TANT - R E C ONNE C T AL L G R OUNDING DE V IC E S
All parts of this appliance capable of conducting
electrical current are grounded. If grounding wires,
screws, straps, nuts or washers used to
complete a path to ground are removed for service,
they must be returned to their original position and
properly fastened.
WAR NING
DISCONNECT UNIT FROM ELECTRICAL POWER SUPPLY
BEFORE MAKING ANY ELECTRICAL CHECKS.
MAXIMUM C UR R E NT L E AK AG E : 0.5 MILLIAMP
MAXIMUM G R OUND PAT H R E S IS TANC E : 0.1 OHM
P OW E R S UP P LY
R AT E D V OLTAG E
115
R E P L AC E ME NT PAR T S
D S C R IP T ION
E
AIRFILTER
COMPRESSOR
CONDENSER FAN
EVAPORATOR FAN
COMPRESSOR CAPACITOR
FAN CAPACITOR
TRANSFORMER
POWER CNTRL ASM
WATER PUMP SWITCH
POWER SUPPLY PCB
CONDENSER FAN MTR
EVAPORATOR MTR
LOUVER MTR
WATER PUMP MTR
PCB BRD OPERATION
CAPILLARY TUBE 22" LONG
CONDENSER ASM
EVAPORATOR ASM

Technical Data

V OLTAG E L IMIT S
103-127
C AT.NO
WJ85X10126
WJ98X10172
WJ94X10204
WJ87X10154
WJ20X10123
WJ73X10135
WJ01X10243
WJ26X10199
WJ26X10201
WJ26X10200
WJ94X10205
WJ87X10153
WJ95X10010
WJ95X10011
WJ26X10197
WJ53X0188
WJ88X10143
WJ87X10155
– 6 –
IMP OR TANT S AF E T Y NOT IC E
This information is intended for use by individuals
possessing adequate backgrounds of electrical,
electronic and mechanical experience. Any attempt
to repair a major appliance may result in personal
injury and properly damage. The manufacturer or
seller cannot be responsible for the interpretation of
this information, nor can it assume any liability in
connection with its use.
APN08AAG1
C UR R E NT-T E MP E R AT UR E C HE C K DATA
A IR T E MP E R AT UR E
C ONDE NS E R IN
˚ F
70
80
90
T E MP E R AT UR E DIF F E R E NT IAL C HE C K DATA
E VA P OR ATOR
A IR T E MP IN
˚ F
70
80
90
APN10AAG1, APH10AAG1
C UR R E NT-T E MP E R AT UR E C HE C K DATA
A IR T E MP E R AT UR E
C ONDE NS E R IN ˚ F
70
80
90
T E MP E R AT UR E DIF F E R E NT IAL C HE C K DATA
E VA P OR ATOR
A IR T E MP IN
˚ F
70
80
90
C OOL ING C UR R E NT
MIN.
MA X.
7.3
7.6
8.7
9.2
9.2
9.9
E VA P A IR T E MP
OUT
˚F
MI
N.
MA X.
42
48
49
55
61
66
C OOL ING C UR R E NT
MIN.
MA X.
8.2
8.7
9.3
9.8
10.2
10.9
E VA P A IR T E MP
OUT ˚F
MI
N.
MA X.
42
48
50
56
60
65

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Apn10 seriesAph10 series

Table of Contents