System Bus Connections; Wiegand Block Connections; Local Bus Connections; Tamper - GE AL-1191 Installation Instructions

Smart card reader
Table of Contents

Advertisement

2
Smart Card Reader
Installation Instructions

System bus connections

Figure 2 shows how to connect the reader to a RAS on the Alli-
ance system bus.
Figure 2. System bus connections
AL-1191/AL-1193
Violet (open collector)

Wiegand block connections

Figure 3 shows how to connect the reader to the Wiegand
connection block on a 4-Door/Elevator Controller DGP.
Figure 3. Wiegand block connections
AL-1191/AL-1193
Control
panel
J10
Green
D-
White
D+
Black
0V
Red
+12V
System bus
RAS
Green
D-
White
D+
Black
0V
Red
+12V
DGP
J8 to J12
1
C
2
C
Violet
4K7
3
C
J13 to J16
Red
+12V
+5V
Black
0V
Green
D0
White
D1
Yellow
L2
Brown
L1
Blue
BZ

Local bus connections

Figure 4 shows how to connect the reader to a 4-Door/Elevator
Controller DGP local bus with a request-to-exit input.
Figure 4. Local bus connections
AL-1191/AL-1193

Tamper

The reader has a tamper feature. When the reader is connected to
the system databus, tamper data is transmitted to the Alliance
system with system data. You can configure a tamper control for
both online and offline operation using an external open collector
output (violet wire)
DGP
J8 to J12
1
C
2
C
Violet
4K7
3
C
J22
Green
D-
White
D+
Black
0V
Red
+12V
BZ
Yellow
Request-to-exit

Advertisement