Output Operation - TOTALINE P374-1 900 Owner's Manual

Heat cool and heat pump dual fuel capable 7-day programmable thermostat
Hide thumbs Also See for P374-1 900:
Table of Contents

Advertisement

Setting a Thermostat Jumper for
Setting a Thermostat Jumper for
Programmable Output Operation
Programmable Output Operation
To control one of the MISC outputs using time, temperature, or
Internet/phone based operation, place the MISC1, or MISC2, or
MISC3 jumper on the terminal labeled PROG (see diagram below).
This extra output will supply 24VAC to the selected MISC terminal
based on the programming described in the following pages. Only
one of the three outputs (MISC1, MISC2, or MISC3) is required to
have this jumper. For more information regarding the MISC1, MISC2,
and MISC3 outputs, please see section 21.
In the diagram below, the MISC1 jumper has
been set for PROG operation.
W3
PROG
HUM
DEHUM
Y2
(MISC1
MISC3
MISC2
MISC1
ONLY)
W1
Y1
G
15
MISC2
CK1
CKGND
R
INSTALL HUMIDITY
MODULE WITH SENSING
ELEMENT OUTWARD
C
MISC3
MISC3
OK
ELEC
GAS
W3
HP
GAS
PROG
B
O
HUM
W2
MISC1
RS2
DEHUM
MISC3
RS+5
Rs1
RSGND
MISC3
MISC2
IMPORTANT CAUTION
NEVER PUT MORE THAN ONE JUMPER
ON THE SAME MISC JUMPER BLOCK!
THIS MAY DAMAGE THE THERMOSTAT
AND VOID YOUR WARRANTY
Page 15.2