Remote Controller Function Manual - Toyotomi GAN GAG A180IV Service Manual

Table of Contents

Advertisement

6 6 6 6 6
Controller Function Manual

Remote Controller Function Manual

Applicable to:
1 Temperature Parameters
Indoor preset temperature (T
Indoor ambient temperature (T
2. Basic Functions
2.1 Cooling Mode
In this mode, the indoor fan will run at preset fan speed. When the compressor stops for outdoor unit malfunction protection,
the indoor fan will still run at preset fan speed.
Under this mode, temperature setting range will be 16-30
2.2 Dehumidifying Mode
Indoor fan will run at low speed invariably. Swing will operate according to setting status.
Under this mode, temperature setting range will be 16-30
2.3 Fan mode
Under this mode, indoor fan motor, swing motor will run at setting status.
Under this mode, temperature setting range will be 16-30
2.4 Heating Mode
In heating mode, if compressor is running, indoor fan will delay to run to avoid cold air blowing. When compressor stops
blowing residual heating will enter. Blowing residual heat: In heating mode, the unit is stopped by remote controller, indoor fan
will continue to run for 60s. Fan speed can not be switched during blowing residual heat.
Under this mode, temperature setting range will be 16-30
2.5 Auto Mode
In this mode, the system selects COOL, HEAT and FAN mode automatically according to the change of ambient temperature.
Protection function is the same as that in cooling and heating mode.
3 Other Control
3 .1 ON/OFF
Each time the On/Off
3.2 MODE Selection
Press the MODE button on the remote controller to select and display the following modes:
AUTO, COOL, DRY, FAN, HEAT,AUTO.
3.3 TEMP. Setting Button
Each time
button is pressed, the set temperature will be increased or decreased by 1 .Adjusting range
is 16~30
. In AUTO mode, this button does not function.
3.4 Manual Button (ON/OFF )
If press AUTO button under off status of the unit, the unit will run under auto mode with swing.If press AUTO button under on
status of the unit,the unit will be stopped.If remote controller command
is given,the mian unit will run under the command.
3.5 TIMER ON/OFF
3.5.1 TIMER ON
The system will continue to run if TIMER ON is set when the system is under ON status. If TIMER OFF is set when the system
is under OFF status, the system will start to run under preset mode upon the time for auto start.
3.5 .2 TIMER OFF
If TIMER OFF is set when the system is under OFF status, the system will maintain its standby status upon the time for auto
stop. If the TIMER OFF is set when the system is under ON status, the system will be stopped upon the tome for auto stop.
Controller Function of Indoor Unit
)
preset
)
amb.
button of the remote controller is pressed, the On/Off state will switch once.
.
.
.
.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gan gag a220iv

Table of Contents