NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
15.Turn the Wick Assembly upside down to replace the Wick Cover.
16. Align the tabs on the wick cover with the four screw holes on the Bottom of the Assembly, as shown, and snap it
into place. Be certain of firm contact at all points.
17. Turn the Wick Adjustment
Knob to the fully raised
position. Pull lightly on the
skirt of the Wick to remove
any slack. Press lightly to
secure the skirt to the
Retainer Teeth on the
Wick Cover.
20. Turn the Wick Adjustment knob to test its operation. Be certain the Wick operates smoothly as the Knob is
turned CLOCKWISE and COUNTER-CLOCKWISE.
21. Test Ignition. Raise the Wick to its full height. The Ignition Plug should be within 3/64" to 5/64"
(1mm to 2mm) of the Wick when the Lever is pulled.
22. Remove Wick Adjustment Knob which you had temporarily replaced to test Wick operation.
23. Replace the CABINET BASE making certain to align the Automatic Safety Shut-off System Lever
and the Wick Adjustment Shaft, which holds the Knob, with the appropriate slots in the CABINET BASE.
Begin by aligning them and gently snap the CABINET BASE in place over the Wick Assembly.
24. Replace the heater Cabinet. Make certain the Guard Grille prongs are inserted securely into the
proper holes on the heater, and the Front Cabinet matches the front of the heater.
25. Fasten the Cabinet to the heater with the two screws.
26. Replace the Wick Adjustment Knob. To be certain it is properly positioned on the Wick Adjustment Shaft,
raise the Wick to its full height.
27. Be sure to check that the wick is set at the correct height of 3/8"(10mm) after reassembling the heater.
18.
Replace the Wick Assembly on
the heater with the Wick raised.
Be sure the rubber seal on tank
is properly seated. You will
need to hold the knob in the
clockwise position to keep the
Wick raised. The Wick adjuster
knob will need to be positioned
between the Caution and
Warning labels. Replace two
diagonally opposite Wing Nuts
first, then the remaining two.
Tighten each of the four Wing
Nuts gradually untill the Wick
assembly is firmly in place.
11
19. While your heater is
disassembled, check the
Automatic Safety Shutoff
system.
Trip the Automatic Shutoff
System by nudging the
Pendulum.
Raise the wick by turning
wick adjuster knob. Trip it
again to make certain it is
operating correctly.