Fig. 3
SIDE BURNER
(If applicable)
Spark Ignitor Adjustment
Occasionally a burner may not ignite within a few seconds after
turning the appropriate control knob counter-clockwise. To adjust
the spark ignitor, use a small needle nose plier to turn the metal
head of the ignitor towards the port (opening) on the burner. DO
NOT TURN THE IGNITOR BY THE CERAMIC BASE. This could
cause damage to the spark ignitor.
FOR E1/E2 AND 500 SERIES GRILLS ONLY
Depending on the grill model, all orifices in the kit may not be used.
E1NK-VGBQ Conversion Kit Part List
(1) Natural Regulator Assembly
(1) Natural Orifice Kit
(3) #37 Grill Burner Orifices
(2) #49 Smoker Burner Orifice
(2) #49 Side Burner Orifies
(2) #48 Infrared Burner Orifices
(1) Natural Conversion Kit Label
E1NK-VGIQ Conversion Kit Part List
(1) Natural Regulator Assembly
(1) Natural Orifice Kit
(2) #37 Grill Burner Orifices
(2) #49 Smoker Burner Orifice
(2) #49 Side Burner Orifies
(2) #48 Infrared Burner Orifices
(1) TruSear
TM
Infrared Burner Valve
(1) Natural Conversion Kit Label
1 1/2"
(3.8 cm)
Air Shutter
Orifice
Distance between
ignitor and burner
port - 1/8" (.32 cm)
Ports (openings)
Metal head
on ignitor
Ceramic Base
E1LPK-VGBQ Conversion Kit Part List
(1) LP/Propane Regulator Assembly
(1) LP/Propane Orifice Kit
(3) #52 Grill Burner Orifices
(2) #57 Smoker Burner Orifice
(3) #57 Side Burner/Infrared Burner Orifices
(1) LP/Propane Conversion Kit Label
E1LPK-VGIQ Conversion Kit Part List
(1) LP/Propane Regulator Assembly
(1) LP/Propane Orifice Kit
(2) #52 Grill Burner Orifices
(2) #57 Smoker Burner Orifice
(3) #57 Side Burner/Infrared Burner Orifices
(1) TruSear
TM
Infrared Burner Valve
(1) LP/Propane Conversion Kit Label
6
VGBQ E1/E2 500 SERIES CONVERSIONS
To convert grill burners, side burner and smoker burner:
1. Remove all grates, flavor generators and stainless steel
burners from the unit.
2. Look into the burner box back toward the control panel in
3/8" (.95 cm)
order to located the orifice hoods. Remove the gas orifice
hoods located on the grill burner valves.
3. Replace the orifice hoods with the correct gas orifice hoods
supplied in the conversion kit. (See chart)
4. Replace the stainless steel burners, flavor generators and
grates.
Rear side of
on burner
control
panel
Smoker Burner
Orifice hood
To convert the rotissiere infrared burner:
1. Remove the back cover from
the unit to expose the orifice
hood to the infrared burner.
2. Remove the gas orifice hood
located on the grill.
3. Replace with the gas orifice
hood supplied in the
conversion kit.
4. Replace the back cover.
Natural
Orifice Hood
Infrared
(1) or (2) - #48 (1) or (2) - #57
Burner
Depending on grill model
To check LP/Propane to Natural Conversion of the rotissiere infrared
burner:
Ignite the rotissere burner and set it to low. If the burner will not
hold a flame, it will be necessary to adjust the low setting. Remove
the control panel to expose the rotissiere safety valve. Using a small
flat head screwdriver turn the adjustment screw counterclockwse.
Visually check the flame. When the burner is able to hold a flame
on the low setting, the setting is complete. Replace the control
panel.
NOTE:
For installation in areas with altitudes greater than 2000 feet, the orifices must be derated at 4% for every
1000 feet above 2000 feet.
Grill
Burners
Smoker
Burners
Side
Burners
Back
Cover
LP/Propane
Orifice Hood
adjustment
screw
7
Natural
LP/Propane
Orifice Hood
Orifice Hood
(4) - #37
(4) - #52
(2) - #49
(2) - #57
(2) - #49
(2) - #57
Landing ledge
Grill Burner /
Side Burner
Orifice hoods
Orifice hood