Download Print this page

Gas Conversion - Viking 100 Series Installation Manual

Conversion kits
Hide thumbs Also See for 100 Series:

Advertisement

IMPORTANT: PLEASE READ AND FOLLOW
1. Before beginning, please read these instructions completely and
carefully.
2. Do not remove permanently affixed labels, warnings, or plates from
product. This may void the warranty.
3. Please observe all local and national codes and ordinances.
CAUTION: Before proceeding with the conversion, shut off the gas
supply to the appliance prior to disconnecting the
electrical power.

GAS CONVERSION

To convert a grill from natural to LP/Propane gas or LP/Propane
to natural, you must use the conversion kit supplied by the
manufacturer. When converting to Natural Gas, use the NKVGBQ
kit for VGBQ models and NKVGIQ kit for VGIQ models. When
converting to LP/Propane, use the LPKVGBQ kit for VGBQ models
and LPKVGIQ kit for VGIQ models. Conversions should only be
done by an authorized service technician.
NOTE: WHEN THE CONVERSION IS COMPLETED, THE
CONVERSION LABEL MUST BE PLACED NEXT TO THE RATING
LABEL UNDER THE DRIP TRAY IN THE REAR LEFT CORNER
NEXT TO THE INLET PIPE.
FOR T/T1/E AND 100/300 SERIES GRILLS
Depending on the grill model, all orifices in the kit may not be used.
TNK-VGBQ Conversion Kit Part List
(1) Natural Regulator Assembly
(1) Natural Orifice Kit
(3) #40 Grill Burner Orifices
(2) #51 Smoker Burner Orifice
(2) #49 Side Burner Orifies
(2) #48 Infrared Burner Orifices
(1) Natural Conversion Kit Label
TNK-VGIQ Conversion Kit Part List
(1) Natural Regulator Assembly
(1) Natural Orifice Kit
(2) #40 Grill Burner Orifices
(2) #51 Smoker Burner Orifice
(2) #49 Side Burner Orifies
(2) #48 Infrared Burner Orifices
(1) TruSear
TM
Infrared Burner Valve
(1) Natural Conversion Kit Label
WARNING
This conversion kit shall be installed by a
qualified service agency in accordance with the
manufacturer's instructions and all applicable
codes and requirements of the authority having
jurisdiction. If the information in these
instructions is not followed exactly, a fire,
explosion or production of carbon monoxide
may result causing property damage, personal
injury or loss of life. The qualified service agency
is responsible for the proper installation of this
kit. The installation is not proper and complete
until the operation of the converted appliance is
checked as specified in the manufacturer's
instructions supplied with the kit.
TLPK-VGBQ Conversion Kit Part List
(1) LP/Propane Regulator Assembly
(1) LP/Propane Orifice Kit
(3) #54 Grill Burner Orifices
(2) #62 Smoker Burner Orifice
(3) #57 Side Burner/Infrared Burner Orifices
(1) LP/Propane Conversion Kit Label
TLPK-VGIQ Conversion Kit Part List
(1) LP/Propane Regulator Assembly
(1) LP/Propane Orifice Kit
(2) #54 Grill Burner Orifices
(2) #62 Smoker Burner Orifice
(3) #57 Side Burner/Infrared Burner Orifices
(1) TruSear
TM
Infrared Burner Valve
(1) LP/Propane Conversion Kit Label
2
VGBQ T/T1/E AND 100/300 SERIES CONVERSIONS
To convert grill burners, side burner and smoker burner:
1. Remove all grates, flavor generators and stainless steel
burners from the unit.
2. Look into the burner box back toward the control panel in
order to located the orifice hoods. Remove the gas orifice
hoods located on the grill burner valves.
3. Replace the orifice hoods with the correct gas orifice hoods
supplied in the conversion kit. (See chart)
4. Replace the stainless steel burners, flavor generators and
grates.
Rear side of
control
panel
Smoker Burner
Orifice hood
To convert the rotissiere infrared burner:
1. Remove the back cover from
the unit to expose the orifice
hood to the infrared burner.
2. Remove the gas orifice hood
located on the grill.
3. Replace with the gas orifice
hood supplied in the
conversion kit.
4. Replace the back cover.
Natural
LP/Propane
Orifice Hood
Orifice Hood
Infrared
(1) or (2) - #48 (1) or (2) - #57
Burner
Depending on grill model
To check LP/Propane to Natural Conversion of the rotissiere infrared
burner:
Ignite the rotissere burner and set it to low. If the burner will not
hold a flame, it will be necessary to adjust the low setting. Remove
the control panel to expose the rotissiere safety valve. Using a small
flat head screwdriver turn the adjustment screw counterclockwse.
Visually check the flame. When the burner is able to hold a flame
on the low setting, the setting is complete. Replace the control
panel.
NOTE:
For installation in areas with altitudes greater than 2000 feet, the orifices must be derated at 4% for every
1000 feet above 2000 feet.
Natural
Orifice Hood
Grill
Burners
(3) - 40
Smoker
Burners
(2) - #51
Side
Burners
(2) - #49
Landing ledge
Grill Burner /
Side Burner
Orifice hoods
Orifice hood
Back
Cover
adjustment
screw
3
LP/Propane
Orifice Hood
(3) - #54
(2) - #62
(2) - #57

Advertisement

loading

This manual is also suitable for:

300 series500 seriesVgbq 100 seriesVgbq 300 seriesVgbq 500 seriesVgiq 100 series ... Show all