Printed Circuit Board) Exchange; Adjustment Volume Location; Test Point Location - Panasonic TH-37PX80B Service Manual

Gph11de chassis
Hide thumbs Also See for TH-37PX80B:
Table of Contents

Advertisement

8.1.3.
P.C.B. (Printed Circuit Board) exchange
8.1.3.1.
Caution
1. To remove P.C.B. , wait 1 minute after power was off for discharge from electrolysis capacitors.
8.1.3.2.
Quick adjustment after P.C.B. exchange
Adjust the following voltages with the multimeter.
P.C.B.
P Board
Vsus
SC Board
Vad
SS Board
Ve
*See the Panel label.
Caution:
Absolutely do not reduce Vsus below Ve not to damage the P.C.B.
8.1.4.

Adjustment Volume Location

8.1.5.

Test Point Location

Name
Test Point
TPVSUS (SS)
TPVAD (SC)
TPVE (SS)
Voltage
Vsus ± 2V
R628 (P)
-105V ± 1V
VR16600 (SC)
Ve ± 1V
VR16000 (SS)
26