5 EXHIBIT PROTECTION SYSTEM

3. PROTECTION SYSTEM

This amplifier uses a very complex protection system. If an error occurs, the amplifier
switches to standby or off mode and prints an error code to the display.
In this way, the protection system is able to avoid a series of potential damages to the
amplifier, but there is no reason to operate carelessly.

3.1. Errors in Power On mode:

Code
17
18
19
20
21
22
23
24
25

3.2. Errors in Standby mode:

Code
33
34
35
36
37
38
39
40
41
42
ALPIN200 Manual © Copyright 2008 by Reimesch Kommunikationssysteme GmbH
Legend
average plate voltage too high
IG2 too high
plate current too high
grid RF too high
problem with output relay contact
screen current too high
HV < 350V for more than 120 ms
HV > 3300V or HV < 1500V
low air for > 90 s
Legend
plate current > 25mA
high voltage > 3300V or high voltage < 1500V
temperature > 115°C
problem with output relay contact
G1 screen current
low air for > 90 s
problem in low voltage supply
drive power > 0.44W
average plate voltage > 480V
G2 screen current > 5mA
14