IMPORTANT SAFETY INSTRUCTIONS This manual contains important safety and operating instructions for the charger. Read the entire manual before using. Also read all instructions and cautions for the charger, batteries and equipment in the vicinity of the batteries. WARNINGS THIS CHARGER SHOULD BE USED TO CHARGE ONLY LEAD ACID, AGM OR GEL CELL TYPE BATTERIES.
Table of Contents Page IMPORTANT SAFETY INSTRUCTIONS INTRODUCING THE CHARGER Personal Safety Precautions Preparing to Charge Precautions INSTALLING THE CHARGER 5 – 15 Choosing a Mounting Location Mounting The Charger Making DC Connections Making AC Connection DC Output Wiring Configurations 7 - 15 OPERATION OF THE CHARGER LED Function Chart...
INTRODUCING THE CHARGER The Guest model 16041, 16082, and 16123 are designed to both recharge your batteries, and extend your battery’s life in applications where it is stored for long periods of time. They are “3-stage” electronic, completely automatic, lightweight, silent, battery chargers and each output produces 12 Volts DC at a full 4 Amps (model specific), while using much less AC current than other charger types.
Preparing to Charge Precautions Before charging a battery with the charger, read the following precautions: Do NOT operate the charger if the cable or an LED indicator is damaged. Make sure all accessories on the product you are charging are OFF. If the battery or batteries must be removed from the product, always remove the grounded terminal from the battery first.
Mounting the Charger Use corrosion resistant #10 sized bolts, backed by a flat washer, and secured to the mounting surface with a split-ring lock washer. Hold the charger to the mounting surface and mark the holes. Remove the charger and drill the mounting holes. Align the charger and assemble the mounting hardware.
DC Output Wiring Configurations This section shows possible DC wiring configurations for the following charger models: 16041, 16082, and 16123. Diagram 1 – 16041 in a single Independent Output configuration 4 Amp Output 1 Group 24...
Page 8
Diagram 2 – 16102 in a dual Independent Output configuration 4 Amp 4 Amp Output 2 Output 1 Group 24 Group 24 Engine Start or Trolling...
Page 9
Diagram 3 – 16082 in a 24VDC, 4 Amp configuration 4 Amp 4 Amp Output 1 Output 1 Group 24 Group 24 Engine Start or Trolling...
Page 10
Diagram 4 – 16082 in a 12VDC, 8Amp configuration 4 Amp 4 Amp Output 1 Output 1 Group 24 Group 24 Engine Start or Trolling...
Page 11
Diagram 5 – 16123 in a triple Independent Output configuration 4 Amp 4 Amp 4 Amp Output 2 Output 3 Output 1 Group 24 Group 24 Group 24 Engine Start or Trolling...
Page 12
Diagram 6 – 16123 in a 36VDC, 4Amp configuration 4 Amp 4 Amp 4 Amp Output 2 Output 3 Output 1 Group 24 Group 24 Group 24 Engine Start or Trolling...
Page 13
Diagram 7 – 16123 in a 12VDC, 4Amp and 24VDC, 4Amp configuration 4 Amp 4 Amp 4 Amp Output 2 Output 3 Output 1 Group 24 Group 24 Group 24 Engine Start or Trolling...
Page 14
Diagram 8 – 16123 in a 12VDC, 4Amp and 12VDC, 8Amp configuration 4 Amp 4 Amp 4 Amp Output 2 Output 3 Output 1 Group 24 Group 24 Group 24 Engine Start or Trolling...
Page 15
Diagram 9 – 16123 in a 12VDC, 12Amp configuration 4 Amp 4 Amp 4 Amp Output 2 Output 3 Output 1 Group 24 Group 24 Group 24 Engine Start or Trolling...
OPERATING THE CHARGER The LED Function Chart below describes the charging process. Display Operating condition When the red LED is on, it indicates that your batteries are discharged and is recharging them at the "BULK" rate (stage 1). This charging rate is 4 Amps. While the red LED is on, the voltage measured (with the charger on) will be approximately 11.8 to 13 Volts.
AC breaker on the main panel when the AC 2. Component failure 2. Return charger to the Guest power is applied. Service Dept. Note: Battery size may be large enough to cause the battery charger to not transition to float stage due to the batteries internal resistance. Hot ambient conditions will make...
SPECIFICATIONS MODEL NUMBERS Specs. 16041 16082 16123 Input Volts 95-135VAC, 95-135VAC, 95-135VAC, (VAC) 50/60Hz 50/60Hz 50/60Hz Input Current (Amax) Banks Output Voltage 12 or 24 12 or 24 or 36 Configurations (VDC) Output Current 4/4/4 DC Cable 4/4/4 Length (ft) Dimensions 1.8 x 5.6 x 5.1...
---Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. LIMITED WARRANTY For two (2) years from the date of original purchase, The Guest Co. will, at its discretion, repair or replace for the original consumer, free of charge, any parts found defective in material or workmanship.