Manuel d’utilisation Français Conditionneur d’air VRVW System Manual de operación Español Sistema de acondicionador de aire VRVW Manuale d’uso Italiano Condizionatore d’aria a sistema VRVW RWEYQ8PY1 RWEYQ10PY1* Εγχειρßδιο λειτουργßαò ëëçíéêÜ RWEYQ16PY1 Κλιìατιστικü ìε σýστηìα VRVW RWEYQ18PY1 RWEYQ20PY1* Gebruiksaanwijzing RWEYQ24PY1 Nederlands...
Page 2
Thank you for purchasing this Daikin air conditioner. Carefully read this Hartelijk dank voor uw keuze voor een Daikin airconditioner. Lees deze operation manual before using the air conditioner. It will tell you how to gebruiksaanwijzing zorgvuldig door voordat u de airconditioner in use the unit properly and help you if any trouble occurs.
RWEYQ8PY1 RWEYQ24PY1 RWEYQ10PY1 RWEYQ26PY1 VRVWIII System air conditioner Operation manual RWEYQ16PY1 RWEYQ28PY1 RWEYQ18PY1 RWEYQ30PY1 RWEYQ20PY1 CAUTION ..Failure to observe these CONTENTS instructions properly may result 1. SAFETY PRECAUTIONS ....... 1 in property damage or personal injury, which may be serious 2.
Page 6
Consult your local dealer regarding what to do Do not start or stop operating the air condi- in case of refrigerant leakage. tioner with the power supply breaker turned When the air conditioner is to be installed in a ON or OFF. small room, it is necessary to take proper mea- Otherwise, fire or water leakage may result.
2. SPECIFICATIONS To avoid injury, do not touch the air inlet or alu- minium fins of the unit. Model Do not place the controller exposed to direct RWEYQ8PY1 RWEYQ10PY1 RWEYQ16PY1 System name sunlight. RWEYQ8PY1 RWEYQ10PY1...
” (air flow flap) with standard control. Before initiating operation, Refer to the chapter “Operation procedure - contact your Daikin dealer for the operation that cor- Adjusting the air flow direction”. responds to your system type and mark. 5. Display “...
9. Display “ ” (inspection/test operation) 25. Thermistor TEST When the inspection/test operation button is It senses the room temperature around the pressed, the display shows the mode in which remote controller. the system actually is. (For servicing only) 26. These button are used when the total heat 10.
6. OPERATION PROCEDURE FOR SYSTEMS WITH COOL/HEAT SELECTOR (Refer to figure 4 and 7) • Operation procedure varies according to the com- Select operation mode with the Cool/Heat bination of BS unit and remote controller. Read selector as follows: the chapter “What to do before operation”. •...
Page 11
Press the operation mode selector button sev- NOTE eral times and select program dry “ ”. • Do not place appliances which produce open fire in places exposed to the air flow from or under the Press the on/off button. indoor unit.
Page 12
3 hours and start the system after NOTE 4 hours, the system will stop after 3 hours and start 1 hour later. • Contact your Daikin dealer in case of chang- ing the combination or setting of group con- trol and two remote controller control systems.
7. OPTIMUM OPERATION 8. MAINTENANCE Observe the following precautions to ensure the HANDLING OF HEAT SOURCE WATER system operates properly. Requests from manufacturer; • Adjust the room temperature properly for a com- • Do not fail to mount a strainer (sold separately as fortable environment.
This is because cool/heat changeover is con- indoor unit for details on how to clean it. trolled by the cool/heat selector. Ask your Daikin • If the water piping may freeze, keep operating the dealer where the remote control switch is heat source water pump operating even during installed.
Page 15
Ask your The unit can absorb the smell of rooms, furniture, Daikin dealer for details on cleaning the unit. This cigarettes, etc., and then emit it again. (*2) operation requires a qualified service person.
3. Operation lamp insufficient; 4. Malfunction code • Check if air inlet or outlet of indoor unit is not Measure: Notify your Daikin dealer and report the blocked by obstacles. malfunction code. Remove any obstacle and make it well-ventilated. If the system shuts down due to an error, the •...
• Check if the heat source of the room is excessive [NOTES] during cooling operation. (1) The circle marks in the columns for corrosion or • Check if the inlet temperature of the heat source scale to develop. water is within its range. (2) Corrosion has a tendency to occur when water Do not exceed its range.
Page 18
• Malfunction: Note 2 Inform the staff of the defective details. This maintenance cycle indicates recommended (Malfunction code being displayed on lengths of time until the need arises for maintenance the remote controller.) work, in order to ensure the product is operational •...
Page 19
Contact your dealer for details. Note: Breakage due to taking apart or cleaning inside by anyone other than our authorized dealers may not be included in the warranty. ■ Moving and discarding the unit • Contact your dealer for removing and reinstalling the total enthalpy heat exchanger when moving house since they require technical expertise.