Printed Circuit Board Connector Wiring Diagram; Indoor Unit Connectors - Haier AS09/12GS2ERA Service Manual

Wall mounted type dc inverter em-series
Table of Contents

Advertisement

4.Printed Circuit Board Connector Wiring Diagram

4.1 Indoor unit Connectors

Connectors
PCB(1) (Control PCB) For HUM09/12HC03/R2(DB)
AS09/12GS2ERA 1U09/12BS1ERA-SM
1) CN26 Connector for fan motor
2) CN1 Connector for heat exchanger thermistor and Room temperature thermistor
3) CN11 Connector for UP&DOWN STEP motor
4) CON2 Connector for power N wire
5) CON1 Connector for power L
6) CN32 Connector for display board
7) C0N6,C0N8 Connector for ions generator
8) CON7 Connector for communicate between the indoor board and the outdoor
board
9) CN27 Connector for fan motor's PG back.
10) CN34 Connector for long-range control
11) CN20 Connector for room card
Note: Other designations
PCB(1) (INdoor Control PCB)
1) SW1 Connector for Forced operation ON / OFF switch
2) SW2 1 Select remote code A or B,2 Select 25 or 35 ,3 Select room card able or
disable
3) SW4 Select 20 or other,if select 20,SW2 must select 25(ON)
4) RV1 Varistor
5) FUSE1 Fuse 3.15A/250VAC
9
Connector Wring Diagram
Domestic Air Conditioner

Advertisement

Table of Contents
loading

This manual is also suitable for:

1u09/12bs1eraAs09gs2eraAs12gs2era1u09bs1era1u12bs1era