Eiki LC-XB41N Service Manual page 39

Hide thumbs Also See for LC-XB41N:
Table of Contents

Advertisement

Electrical Adjustments
Group/
Item Name
Item
4 DIMMER_CTRL_LEVEL5
5 DIMMER_CTRL_LEVEL6
6 DIMMER_CTRL_LEVEL7
7 DIMMER_CTRL_LEVEL8
8 DIMMER_CTRL_LEVEL9
9 DIMMER_CTRL_LEVEL10
10 DIMMER_CTRL_LEVEL11
11 DIMMER_CTRL_LEVEL12
12 DIMMER_CTRL_LEVEL13
13 DIMMER_CTRL_LEVEL14
14 DIMMER_CTRL_LEVEL15
15 DIMMER_AVERAGE_POINT
16 DIMMER_AVERAGE_DATA
17 DIMMER_LEVEL_AUTO
18 DIMMER_LEVEL_NORMAL
19 DIMMER_LEVEL_ECO
20 Lamp check enable
21 VOLTAGE_LEVEL
22 DIMMER_LEVEL_HIGH
Group 250 FAN Cntorol
0 FAN1 MIN ADJUST (DAC)
1 FAN1 MAX ADJUST (DAC)
2 FAN2 MIN ADJUST (DAC)
3 FAN2 MAX ADJUST (DAC)
4 FAN3 MIN ADJUST (DAC)
5 FAN3 MAX ADJUST (DAC)
6 Not used
7 Not used
Group 251
Not used
Group 252 Fan Option
0 HI-LAND SWITCH
1 SAFETY SWITCH
2 FAN MANUAL SWITCH
3 FAN1 MANUAL VOLTAGE
4 FAN2 MANUAL VOLTAGE
5 FAN3 MANUAL VOLTAGE
6 Not used
Group 253 Fan Tem Error Setting (Memorized)
0 Temp A Warning (High)
1 Temp B Warning (High)
2 Temp C Warning (High)
3 Temp B-A Warning (High)
4 Temp C-A Warning (High)
5 Temp A Warning (Normal)
6 Temp B Warning (Normal)
7 Temp C Warning (Normal)
8 Temp B-A Warning (Normal)
9 Temp C-A Warning (Normal)
10 Temp A Warning (Eco)
11 Temp B Warning (Eco)
12 Temp C Warning (Eco)
13 Temp B-A Warning (Eco)
Function
Luminance Level 5 Data for Dimmer: Dim
Level 5 at the less than the Value
Luminance Level 6 Data for Dimmer: Dim
Level 6 at the less than the Value
Luminance Level 7 Data for Dimmer: Dim
Level 7 at the less than the Value
Luminance Level 8 Data for Dimmer: Dim
Level 8 at the less than the Value
Luminance Level 9 Data for Dimmer: Dim
Level 9 at the less than the Value
Luminance Level 10 Data for Dimmer: Dim
Level 10 at the less than the Value
Luminance Level 11 Data for Dimmer: Dim
Level 11 at the less than the Value
Luminance Level 12 Data for Dimmer: Dim
Level 12 at the less than the Value
Luminance Level 13 Data for Dimmer: Dim
Level 13 at the less than the Value
Luminance Level 14 Data for Dimmer: Dim
Level 14 at the less than the Value
Luminance Level 15 Data for Dimmer: Dim
Level 15 at the less than the Value
Luminance Data Avarage Point for Mimmer
Luminance Data Avarage Value for Dimmer
Current Dimmer Leverl
Normal Dimmer Level
Eco Dimmer Level
Lamp Voltage
Dimmer level High
DAC Output for Fan
Adjust the tolerance of DAC and Fan Volage.
* Lamp mode is forced Eco
0: Normal, 1: Hi-Land, 2-4: Hi-Land 1-3
For test purpose
0: Auto, 1: Manual
Fan Voltage (unit : 0.1V)
Effective only when Fan Maual switch is 1
Temp. A to judge the Temp Error at High
(Room)
Temp. B to judge the Temp Error at High
(Panel)
Temp. C to judge the Temp Error at High
(Lamp)
Temp. B-A to judge the Temp Error at High
(Clogging Det.)
Temp. C-A to judge the Temp Error at High
(Clogging Det.)
Temp. A to judge the Temp Error at Normal
(Room)
Temp. B to judge the Temp Error at Normal
(Panel)
Temp. C to judge the Temp Error at Normal
(Lamp)
Temp. B-A to judge the Temp Error at Normal
(Clogging Det.)
Temp. C-A to judge the Temp Error at Normal
(Clogging Det.)
Temp. A to judge the Temp Error at Eco (Room)
Temp. B to judge the Temp Error at Eco (Panel)
Temp. C to judge the Temp Error at Eco (Lamp)
Temp. B-A to judge the Temp Error at Normal
(Clogging Det.)
Initial
10
225
10
225
10
225
0
0
0
100
100
100
HiLand-
HiLand-
Normal
Ceiling
Normal
Ceiling
53
53
51
51
63
63
62
62
67
67
68
68
100
100
100
100
100
100
100
100
52
52
50
50
63
63
62
62
67
67
67
67
100
100
100
100
100
100
100
100
51
51
49
49
62
62
61
61
67
67
66
66
100
100
100
100
-39-
Range
Note
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 16
-
* Read only
-
* Read only
0 - 15
0 - 15
0: Lamp Failure Detection OFF (White 50%
Back), 1 : ON (Blue 100% Back)
Unit: 8bit(Raw Data) * Read only
0 - 15
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 5
0 - 6
0 - 3
0 - 255
0 - 255
0 - 255
30-100
30-100
30-100
0-100
0-100
30-100
30-100
30-100
0-100
0-100
30-100
30-100
30-100
0-100

Advertisement

Table of Contents
loading

Table of Contents