Functions

Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
• Room temperature sensor. (Thermistor)
• Pipe temperature sensor. (Thermistor)
Room temperature control
• Maintain the room temperature in accordance with the Setting Temp.
Starting the Current Control
• Indoor fan is delayed for 5 sec at the starting.
Time Delay Safety Control
• Restarting is for approx. 2 minutes.
Indoor Fan Speed Control
• Super High, High, Med, Low
Operation indication Lamps (LED)
--- Lights up in operation
--- Lights up in Sleep Mode
--- Lights up in Timer Mode
--- Lights up in Preheat Mode (for Heating Model)
--- Lights up in Plasma Air Clean Mode
PLASMA
Soft Dry Operation Mode
• Intermittent Operation of fan at low speed or off.
Sleep Mode Auto Control
• The fan is switched to low(Cooling), low(Heating) speed.
• The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
Natural Air Control by CHAOS Logic
• The fan is switched to intermittent or irregular operation
• The fan speed is automatically switched from high to low speed.
Airflow Direction Control
• The louver can be set at the desired position or swing
up and down automatically.
PLASMA
• The function will be operated while in any
operation mode with selecting the function.
• The function is to be stopped while it is
operating with selecting the function.
Defrost(Deice) control (Heating)
• Both the indoor and outdoor fan stops
during defrosting.
Hot-start Control (Heating)
• The indoor fan stops until the
evaporator pipe temperature will be
reached at 34°C.