6-2 PTC AND OLP

Normal operation of
Compressor is
impossible or poor.
Separate PTC-Starter
from Compressor and
measure resistance
between No. 5 and 6
of PTC-Starter with a
T ester.
(Figure 14)
Shows continuity
Separate OLP from
Compressor and check
resistance value
between two terminals
Open
of OLP with a T ester.
(Figure 15)
Figure 14
- 12 -
Observation value is
115V/60Hz : 6.8 ±30%
The resistance value
is 0
(short) or
(open).
Check another
electric component.
Replace OLP .
Figure 15
Replace PTC-
Starter.