SECTION 2 | DESCRIPTION RC-200 is a wired Remote Control that is compatible with the following series of Inverters: PST-1500-12, PST-1500-24; and PST-2000-12, PST-2000-24. It is used to switch oN and switch off the inverter from a remote location. It also displays the operational status using LCD display and colored LeDs.
Page 3
(NOTE: All dimensions in mm) 2. Push Button to Change Display Screen 3. LCD Screen 4. LED - “Overload” 5. LED - “Over Temp” 6. LED - “Power” 7. RJ-50 Modular Jack Fig. 1 Remote Control RC-200 - Layout and Dimensional Drawing...
LCD - Data LCD - Ground Fig. 2 Remote Control RC-200 - Pinout of Modular Jack RJ-50 The standard numbering system of the pins of a Modular Jack, when looking into the Jack, is from left to right. As the conductors of the cable are cross-connected...
SECTION 4 | INSTALLATION Please refer to fig. 1. The Remote Control can be flush mounted on a wall or a panel by making a suitable cut-out to accommodate the projection in the back. Connect one end of the cable set to the RJ-50 Modular Jack (7) at the back and the Remote and the other end to the RJ-50 Modular Jack on the inverter.