  • Page 2 Power Grid Reset to-use touch screen. To program or adjust status button indicators your LS-90, simply touch your finger or the stylus firmly to the screen. The screen will Home button automatically light up and you will hear a SA VE EN ER GY “beep.”...
  • Page 3: Control Screens

    HOME pg2, MENU pg3, and MANUAL pg4. The LS-90 touch screen technology allows you to select (by touching) an item and change it using the +/- buttons on the control bar. All user inputs use this method. If you want to change it, touch it.
  • Page 4: Menu Screen

    MENU Screen The MENU screen is the gateway to many functions of the LS-90. It is displayed when you press the purple MENU button on the control bar to the right side of the screen. Note page numbers for further info about each function.
  • Page 5: Manual Screen

    MANUAL Screen The Manual Screen control screen is where you can make temporary changes to your LS-90’s operation. The LS-90 has 6 manual override commands. These are accessed by pressing the +/- buttons AUX heat FRESH AIR or touching the current temperature on the...
  • Page 6 FRESH AIR - If you have a fresh air baffle connected to the EX terminal, the LS-90 will use this outside air source as the 1st stage of heating or cooling. Useful in desert climates where outside air temp can change very quickly or just to freshen indoor air quality.
  • Page 7 Programming Using the Interview Method (Fastest and Easiest ): Interview 1. Make sure the LS-90 is in either HEAT or Scroll control Calendar COOL using the MODE button 2. Press MENU on the control bar and then touch PROGRAM in the upper left of the screen. The PROGRAM BY INTERVIEW screen will come up.
  • Page 8 The LS-90 will generate a simple program for you. It will assume you are home on the weekend and just apply your wake-up and evening temp choices. Your LS-90 is now programmed and ready to go. No additional updates are needed. If you would like to fine-tune the LS-90 programming, including adding or deleting time periods, or reviewing your schedule, please refer to the instructions that follow regarding programming using the Calendar method.
  • Page 9 LS-90 setting and the room temperature required before the heating or cooling system will turn on— from 0.5° to 2.0° F (.25° to 1° C). For example, if HVAC CYCLING is set to 2.0° F and the LS-90 is set to 70°F, the heat cycle will not start until the room temperature drops to 68°. Similarly, the cooling...
  • Page 10 To set/adjust HVAC CYCLING: 1. Press Menu and then touch “COMFORT.” 2. Touch the temp offset setting. 3. Use the +/- buttons to raise or lower the variance setting—from 0.5° to 2.0° F. 4. Press HOME to return to the Home screen. 2ND STAGE ON AT : This feature allows you to adjust the settings that control second stage heating and cooling depending upon the climate you live in.
  • Page 11 (You cannot change MAX humid % until you set it to ALWAYS or HST+TST) 3. The LS-90 can be toggled to <ALWAYS> run the air conditioner when the humidistat calls to de- humidify or can be set to run the air conditioner only when the humidistat calls to de-humidify AND the...
  • Page 12 Consumables are parts of your HVAC system that get used up; like filters and UV bulbs. The LS-90 keeps track of system run times and can be programmed to remind you when consumables, such as air filters, humidifier pads and UV bulbs, should be checked and/or changed.
  • Page 13 HVAC system. FAN CTRL TSTAT BACK> IMPORTANT: Make sure the LS-90 is powered up and is in the OFF mode before set-up. (To turn your thermostat OFF, press the Power button and select OFF.) Heating and cooling systems must be configured separately.
  • Page 14 NOTE: Most heat pump systems have electric heat strips for auxiliary heat. 7. Fan Control is by the LS-90 (tstat) for heat pumps. 8. Press HOME button to return to the Home screen. NOTE: For heat pump system your cooling is...
  • Page 15 Displays info and interactive screens from a network source. Refer to your NETWORK system manual. LOCK The LS-90 has 2 lock features. These control the users ability to change the temperature and other settings of the LS-90. 1 2 : 3 0 p m W E D 7 4...
  • Page 16 Calibrate controls CALIBRATE 1 2 : 3 0 p m W E D CALIBRATE Your thermostat was accurately calibrated at the factory to ±1° F of actual ambient temperature. DELTA You do have the option, however, to change the FACTOR display temperature to match that of a previous thermostat, or to match another thermostat already in your home, from ±1 - 9°F (±1-5°C).
  • Page 17 Save Energy Button SAVE ENERGY The “Save Energy” feature on the LS-90 provides a simple, easy- control to-use way to help you manage your energy use. SAVE ENERGY automatically adjusts your target temperature up [in COOL] or SA VE EN ER GY...
  • Page 18 Unlike other manufacturers, the LS-90 TRUE AUTO has no temperature or time limitations (Patent pending), just program your desired HEAT and COOL temps and select the AUTO mode. The LS-90 will switch from HEAT to COOL as needed.
  • Page 19 The NETWORK button allows you to identify the network you are connected with and further manage your settings. You can connect your LS-90 to an AMI network for In Home Display of electric meter data or connect to a Home Automation network for HA functionality with remote access to your HVAC system and home conditions.
  • Page 20 They can display text and alpha numeric information on energy use, HVAC status, and other network connectivity. These messages are generated by another network source and displayed on the LS-90. Consult your AMI or Home Automation network documentation for further information. sample INFORMATION screen...