Customer system your Notes LS-90 Installation Guide Caution • Your thermostat is a precise instrument, handle it with care. • Turn off electricity to the HVAC system before installing or servicing thermostat or any part of the system. •...
You will need a small Phillips screwdriver and a drill with 3/16-in. (4.8mm) bit for wall mounts. LOCATION Replacement installations - mount the LS-90 in place of the thermostat. You must have a “C” wire or other 24VAC power available at the LS-90 location. A new location will require moving your wiring.
Reference page 13 for better understanding of wire labels from different HVAC system makers. IMPORTANT: C wire or 24VAC power is required for the LS-90 to operate. If you do not have a C wire you can run a new wire from the HVAC to the LS-90 or provide 24VAC power to operate the LS-90 using a standard 24VAC wall transformer.
With all the wires connected (including the C wire), it is time to turn the AC power back on. Do this at the breaker you used to switch it off. The LS-90 will power-up in the control OFF mode. Your LS-90 is not con gured to operate your HVAC system yet.
5. If you have AUXILIARY heat, touch the number of stages (default is [NONE] ) use the +/- buttons to select 1-2 stages. (NOTE: The LS-90 controls a maximum of 3 stages total between pump and AUX.) 6. (If you have AUX) Select the type of auxiliary heat that you have - Electric or Gas-Oil.
Page 6
Congratulations, you have successfully installed your unit. Please proceed to the OPERATING SA VE Guide to initialize the LS-90. EN ER GY IMPORTANT: After you have labeled and connected your wires, TA R G ET TE M P and followed the correct HVAC set-up, if these check procedures do...
POWER ADPT H or DH RELAY WIRE REFERENCE CHART LS-90 Terminal Your Wires R or V or VR RH and RC Single power for HEAT and COOL RH or 4 RH Power for HEAT (RH not connected to RC jumper clip removed)
Page 8
Zoned Systems Reference Your Wires Radio Thermostat Terminal 2 wire Zoned Hot Water 3 Wire Zoned Hot Water Motor Driven Valves R or 5 RH (power) W or 4 W (heat ON) Y or G or 6 (the 3rd wire) A (heat OFF) 3 Wire Zoned Hot Water Solenoid Valves RH (power)