Greyhound 65075 Set-Up & Operating Manual page 21

22 ton
Table of Contents

Advertisement

problem
Output pressure
varies
No intake of
chemicals.
Follow all safety precautions whenever diagnosing or servicing the
equipment or engine.
please read tHe FolloWing careFully
THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY
DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR
DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT
HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS
QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/
OR DISTRIBUTOR ExPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD
BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE
BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE
ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER
INSTALLATION OF REPLACEMENT PARTS THERETO.
SKU 65075
For technical questions, please call 1-800-444-3353.
troubleshooting
possible causes
1.
Not enough water supply.
2.
Water inlet screen is clogged.
3.
Nozzle is clogged.
4.
Nozzle has mineral build up.
1.
Chemical hose not properly
inserted into unit.
2.
Tube cracked or split.
3.
Wrong Nozzle.
4.
Injector turned off.
5.
Injection tube strainer clogged.
6.
Nozzle blocked.
7.
Dried chemicals in injector.
probable solutions
1.
Check water supply hose for kinks,
leaks, or blockage. Open faucet all
the way.
2.
Remove inlet screen and rinse out.
3.
Remove Nozzle and clean.
4.
Remove Nozzle and clean with
vinegar.
1.
Push firmly into injector. Replace
tube.
2.
Switch to black Nozzle.
3.
Turn collar counterclockwise.
4.
Clean strainer.
5.
Clean Nozzle.
6.
Dissolve by running warm water
through the injection tube.
7.
Run clean water through injector
until clear.
Page 21

Advertisement

Table of Contents
loading

Table of Contents