ILDV20/30/40 Fireplace Insert

VeNtiNG RequiReMeNtS

Make sure the exhaust pipe on heater connects to exhaust
portion of cap. Attach flex liners. Figure 6
Do not crimp or rupture liner when bending it into chimney
offsets.
The exhaust vent must reline the entire length of chimney and terminate above chimney top.
Vent must meet all vent manufacturer's requirements when installed.
Make sure you have the following before installing unit:
3" and 3" UL 1777 Listed gas liner for air inlet and exhaust.
Vertical Terminations kits:
iLDV20/iLDV30: HEDV3T81, HEDV3T11, HEDVRT, AI31TK33A
iLDV40: HEDV3T81, HEDV3T11, HEDVRT
Figure 6
Venting Unit
1
Inlet
Exhaust
FP1922
vent requirements
9/08
Maximum Height 40'
(1.9 m)
Minimum Height 10'
(3 m)