Operating Manual Electronic Temperature Controller Type TRN, TRN/20, TRM, TRM/20, TRH and TRH /20 Gas sampling and conditioning technology 2-5.1.2-ME...
Page 2
Dear Customer, we have made up this operating manual in such a way that all necessary information about the product can be found and understood quickly and easily. Should you still have any question, please do not hesitate to contact M&C directly or go through your appointed dealer.
Head Office M&C TechGroup Germany GmbH Rehhecke 79 40885 Ratingen Germany Telephone: 02102 / 935 - 0 Fax: 02102 / 935 - 111 E - mail: info@mc-techgroup.com www.mc-techgroup.com GENERAL INFORMATION The product described in this operating manual has been examined before delivery and left our works in perfect condition related to safety regulations.
SAFETY INSTRUCTIONS Please take care of the following basic safety procedures when mounting, starting up or operating this equipment: Read this operating manual before starting up and use of the equipment. The information and warnings given in this operating manual must be heeded. Any work on electrical equipment is only to be carried out by trained specialists as per the regulations currently in force.
USED TERMS AND SIGNAL INDICATIONS This means that death, severe physical injuries and/or important material damages will occur in case the respective safety measures are not fulfilled. D A N G E R ! This means that death, severe physical injuries and/or important material damages may occur in case the respective safety measures are not fulfilled.
Three temperature control ranges are available: TRN = 0-100°C, TRM = 0-200°C, TRH = 0-250°C. The desired operating temperature can be set using the control knob with its graduated scale. The control function is displayed by LED. A clear cover shows the set value and the switch function, thus ensuring that the desired value has not been changed unattended.
RECEIPT OF GOODS AND STORAGE • Immediately after arrival, remove the controller and eventual accessories carefully from the packing and check the articles for completeness against the packing list; • Check the goods for any damage during transportation and, if required, inform your shipping insurance immediately of the damage found.
TR N/ M/ H and must be a maximum of 4,600 watt in the case of TR N/ M/ H/ 20. W A R N I N G ! Temperature controllers TRN, TRM, TRH Temperature controllers TRN/20, TRM/20, TRH/20 with 7-pin coupling socket 10A...
• Check whether the controller is functioning properly: ⇒ Set maximum desired temperature yellow LED lights up When the desired temperature is reached ⇒ controller switches heating off, yellow LED goes out. On installation, the controller should basically be checked to see whether it switches at the set values and reaches the desired operating temperature.