  • Page 1 User manual...
  • Page 2: Table Of Contents

    E cient water use, recyclable lters 10. FILTER CHANGE AND MAINTENANCE RECORD ..28 Plug & Play Ready to connect 11. NOTES ..............30 12. ZIP GUARANTEE CERTIFICATE .........31 Please keep this manual, including service and guarantees sections, to provide a reasonable after-sales service.
  • Page 3: Presentation

    2.1 What is natural osmosis and reverse osmosis? Thank you and congratulations on selecting the ZIP Water Purifier. ZIP purifiers are among the best appliances you can find on the Natural or direct osmosis is common in nature, found in places market to improve water taste and quality.
  • Page 4: How Does The Membrane Work

    The the pores of the membrane, while the rest of the water (water reverse osmosis membrane of the ZIP Purifier is able to reduce the rejected with high salt concentration) will be diverted back to the concentration of elements and compounds listed in the following supply pitcher to recycle and optimise performance.
  • Page 5 FOR PRESSURE FACTOR CONVERSION Pressure (Bar) About production Salt rejection (%) 0,70 0,17 1,00 0,25 1,50 0,33 1,75 0,42 2,50 0,58 4,00 1,00 4,50 1,08 4,90 1,17 5,20 1,25 5,80 1,42 Register Your Zip at www.zipwater.co.uk Register Your Zip at www.zipwater.co.uk...
  • Page 6: System

    Do not use with water that is microbiologically unsafe, ZIP is designed for TDS up to 800 ppm. For TDS above 800 ppm, of unknown quality, or without adequate disinfection consult your dealer. (If the water being used is from a UK public before or after the system.
  • Page 7: System Installation

    • Turn the control dial from the “0” position to the “1” position. • Plug the transformer wire into the power socket on the back of the ZIP. Plug the electric cord into a wall socket. • For cleaning the reservoirs use a sponge and soap.
  • Page 8: Use Of Equipment

    • If you plan to not use the purifier for more than one week, completely empty the water supply pitcher and pure water reservoir, and disconnect the power supply. Register Your Zip at www.zipwater.co.uk Register Your Zip at www.zipwater.co.uk...
  • Page 9: Recommendations For The Correct Use Of Osmotic Water

    • Wash both reservoirs with a soft cloth and soap and water. Pay special attention to the hygiene of the dispenser regularly and especially at the time of the periodic maintenance. Always use a clean cloth for cleaning the ZIP Unit. 4.5 Recommendations for the correct use of Os- motic water.
  • Page 10: User Interface

    / ZIP ZIP / User manual 5. Operation of the equipment / 19 The chart below shows the condition of the ZIP by colour coding. Filtered water is then pumped to the membrane, making the reverse osmosis process possible. VISUAL FUNCTION...
  • Page 11: Maintenance And Consumables

    STARTING A WATER TREATMENT CYCLE It’s very important to ensure that your system is kept clean, sanitary In order to guarantee the and that the filters are regularly replaced using orginal ZIP filters, by quality of the produced wa- authorised dealers only.
  • Page 12: System Components

    Remove the new filter from packaging and insert into the purifier by gently pushing upwards while rotating counter- clockwise until seated in place. To change the postfilter, proceed as follows.. Register Your Zip at www.zipwater.co.uk Register Your Zip at www.zipwater.co.uk...
  • Page 13 Slide the collet sleeve out and replace the safety clip under the collet sleeve. 13. Mount the postfilter back into the retaining clips and replace a back cover. Register Your Zip at www.zipwater.co.uk Register Your Zip at www.zipwater.co.uk...
  • Page 14: Troubleshooting

    7. LED off 7. LED off After any maintenance, please ensure absence of leaks in the sys- tem by means of a visual inspection while the system makes two complete cycles. Register Your Zip at www.zipwater.co.uk Register Your Zip at www.zipwater.co.uk...
  • Page 15: Filter Change And Maintenance Record

    REPAIR EXTRAORDINADY SANITIZATION GUARANTEE SANITIZATION GUARANTEE OTHERS OTHERS START-UP Technical START-UP Technical COMPLETE MAINTENANCE Stamp ORDINARI COMPLETE MAINTENANCE Stamp ORDINARI REPAIR EXTRAORDINADY REPAIR EXTRAORDINADY SANITIZATION GUARANTEE SANITIZATION GUARANTEE OTHERS OTHERS Register Your Zip at www.zipwater.co.uk Register Your Zip at www.zipwater.co.uk...