Summary of Contents for Puricom Europe columbia aqua FC-1300-ROP

  • Page 1 FC-1300-ROP FC-1300-F FC-1300-UF Technical Manual Service Booklet...
  • Page 3: Table Of Contents

    INDEX 1. PRINCIPAL CHARACTERISTICS 2. TECHNICAL CHARACTERISTICS 3. HOW TO GET WATER FROM YOUR DISPENSER 4. IDENTIFYING THE MANAGEMENT AND CONTROL COMPONENTS 5. USER INTERFACE 6. HOW TO ACCESS THE FILTERS 7. WARRANTY 8. RECORDING SHEET FOR THE INSTALLATION AND STARTING UP OF THE EQUIPMENT. TECHNICIAN 9.
  • Page 4: Principal Characteristics

    1. CARACTERÍSTICAS PRINCIPALES DIRECT ACCESS Ease of access and maintenance Facilidad de acceso y mantenimiento COLUMBIA FILTERS Fast connection, original Columbia filters Filtros originales Columbia de conexión rápida. CAPSULATED MEMBRANE Membrane Installed. Maximum hygiene Membrana Instalada. Máxima higiene REMINERALIZER Post-filter that adjusts the pH Postfiltro ajustador de pH CLICK Rapid and highly secure connections...
  • Page 5: Technical Characteristics

    2. TECHNICAL CHARACTERISTICS Application Water Treatment 2. CARACTERÍSTICAS TÉCNICAS • Reverse osmosis (ROP Model) • Filtration (F Model) • Ultrafiltration (UF Model) • Mejora de las características del agua potable (que cumpla con los requisitos de la Directiva Europea sobre Agua de consumo humano 98/83 o sus trasposicio- nes nacionales en los distintos estados miembros de la Comunidad Europea).
  • Page 6 1 Sediment Prefilter 1 Sediment Prefilter 1 Sediment Pefilter Treatment: 2 Carbon Prefilters 1 Carbon Prefilter 1 Carbon Prefilter 1 RO 80 GPD Membrane 1 Ultrafiltration cartridge 1 Postfilter to adjust pH Pre and Prefilter Conne- cetions : IN / ENTRADA Inlet: ¼”...
  • Page 7 HYDRAULIC SCHEME – F MODEL FLOAT VALVE VÁLVULA FLOTADOR SHUT-OFF LLAVE VALVE DE PASO UPPER RESERVOIR DEPÓSITO SUPERIOR HYDRAULIC SCHEME – UF MODEL FLOAT VALVE VÁLVULA FLOTADOR SHUT-OFF LLAVE VALVE DE PASO UPPER RESERVOIR DEPÓSITO SUPERIOR...
  • Page 8 ELECTRIC SCHEME – RO MODEL ELECTRIC SCHEME – UF AND F MODELS...
  • Page 9 ROP MODEL HYDRAULIC CONNECTION SCHEME DRAIN INLET U AND UF MODELS HYDRAULIC CONNECTION SCHEME INLET...
  • Page 10: How To Get Water From Your Dispenser

    3. HOW TO GET WATER FROM THE DiSPENSER • To get cold water: Press with the cup the right lever of the dispenser so that cold water begins to flow (1) • To get hot water: Press the button with the padlock icon while you push the lever on the left with your cup so that hot water begins to flow (2)
  • Page 11: Identifying The Management And Control Components

    4- IDENTIFYING THE MANAGEMENT AND CONTROL COMPONENTS Upper Cover Cubierta superior Power supply indicator Indicador alimentación Hot water switch eléctrica Interruptor agua Hot water indicator Indicador agua caliente caliente Cold water indicator Eco-sensor Indicador agua fría Interruptor Cold water switch Ajuste agua fría Eco-sensor adjustor...
  • Page 12: User Interface

    5. USER INTERFACE 6. HOW TO ACCESS THE FILTERS Extract the drip tray by pulling it. Extract the bolt situa- The equipment features light indicators placed over hot ted over the lid that remains uncovered once the drip and cold-water cooler to indicate the equipment’s va- tray has been pulled away.
  • Page 14: Warranty

    17. WARRANTY EQUIPMENT WARRANTY ADDRESSED TO THE END-USER: The equipment was installed and El equipo queda instalado y en funciona- GARANTÍA DEL EQUIPO DIRIGIDA AL USUARIO FINAL: functions satisfactorily for the client miento de forma satisfactoria para el The distributor guarantees the equipment for a period of two years for any lack of El distribuidor garantiza los equipos durante el período de dos años ante cualquier falta and for the record: cliente y para que conste:...
  • Page 15: Recording Sheet For The Installation And Starting Up Of The Equipment. Technician

    18. RECORD SHEET FOR THE INSTALLATION AND COMMISSIONING OF THE EQUIPMENT. TECHNICIAN COMMENTS: NOTES FOR THE TECHNICIAN/INSTALLER: Read this Manual carefully. If you have any COMENTARIOS NOTAS PARA TÉCNICO/INSTALADOR: Lea atentamente el presente Manual. Ante cualquier doubts, get in touch with the Technical Assistance Service (T.A.S) of your distributor. Results of the installation and set-up: duda, póngase en contacto con el servicio de atención técnica (S.A.T.) de su distribuidor.
  • Page 16 19. EQUIPMENT INSTALLATION AND COMMISSIONING RECORD SHEET. TECHNICIAN NAME, SIGNATURE AND SEAL OF DATE TYPE OF SERVICE FECHA TIPO DE SERVICIO NOMBRE, FIRMA Y SELLO THE AUTHORIZED TECHNICIAN DEL TÉCNICO AUTORIZADO TECHNICIAN SET-UP PUESTA EN MARCHA TÉCNICO ORDINARY ORDINARIA FULL MAINTENANCE SEAL MANTENIMIENTO COMPLETO SELLO...
  • Page 17: Service Booklet. User

    19. SERVICE BOOKLET. USER NAME, SIGNATURE AND SEAL OF DATE TYPE OF SERVICE FECHA TIPO DE SERVICIO NOMBRE, FIRMA Y SELLO THE AUTHORIZED TECHNICIAN DEL TÉCNICO AUTORIZADO SET-UP TECHNICIAN PUESTA EN MARCHA TÉCNICO ORDINARY ORDINARIA FULL MAINTENANCE SEAL MANTENIMIENTO COMPLETO SELLO REPARATION EXTRAORDINARY...