Magnum 6500 Owner's Manual page 38

Corn/wood pellet furnace
Table of Contents

Advertisement

PROBLEM
? Fire goes out or stove shuts down
automatically.
? Fuel will not feed.
? Furnace runs for 30 minutes and then
shuts down.
? Blower will not shut off after the fuel
has been switched off and the stove has
cooled down.
The leading reason that the appliance shuts down, will not produce heat or runs erratically is because the venting, fresh air or
ducting system was not installed properly. If the ducting system is correct, the venting system balanced and the fuel is clean
and dry, the furnace will operate as designed.
CAUSES
Hopper is empty.
Fuel is not feeding.
High limit temperature switch has
tripped.
Too much air to firepot.
Fuel feed high or low.
Hot air vents are closed
Dirty filter
Hopper is empty.
Auger, circuit board, high limit
switch tripped
A foreign object is caught in auger
Fuel is dirty and or wet
Auger motor is bad or loosened
Exhaust
gas
is
not
temperature. Started on too low of
Setting.
Low limit snap switch not operating
correctly; may be defective.
Wires to either the low limit snap
switch (mounted on the side of the
firebox or exhaust manifold) are
loose or disconnected.
Fan Limit switch has failed in the
closed position.
Unit has not cooled down yet.
Fan Limit switch has stuck
38
SOLUTIONS
 Refill hopper.
 See "Pellets will not feed" below.
 Allow furnace to cool for 1 hour
and relight.
filter to make sure that enough air is
passing through the system. Clean
or replace if dirty. Do not restrict
panel vents on furnace.
 Adjust
the
combustion airflow.
 Have your Magnum reseller adjust
the fuel control.
Open all registers. Too much heat
in supply lines has caused in line sensor
to shut system down. Make sure filter is
clean to let enough air pass thru system.
 Check contents of the hopper. Add
fuel if necessary.
 Have
your
diagnose the problem and replace
the parts.
 Relight the furnace.
up
to
Start on higher setting
 Have your Magnum
replace the low limit switch.
 Contact
your
reseller for service.
 Have your Magnum
replace the Fan Limit control.
 It can take up to 1 hour for the unit
to cool down enough for the blower
to shut off. If it takes longer than 2
hours for the blower to shut off or if
it fails to shut off contact your local
Magnum service technician.
Tapping on the switch will free up a
sticky switch. Make sure electrical
is unplugged
Check your furnace
damper
to
reduce
Magnum
reseller
reseller
local
Magnum
reseller