Carrier Low-Boy 58CLR Product Data
Carrier Low-Boy 58CLR Product Data

Carrier Low-Boy 58CLR Product Data

Low-boy oil furnace input capacities: 70,000 thru 154,000 btuh series 120
Hide thumbs Also See for Low-Boy 58CLR:

Advertisement

Quick Links

58CLR
Low---Boy Oil Furnace
Input Capacities: 70,000 thru 154,000 Btuh
Series 120
THE LATEST IN OIL FURNACE
TECHNOLOGY
The model 58CLR combines high efficiency and quiet operation
with oil heating technology. The 58CLR is available in 2 sizes.
Each size can be fired at 3 different rates by a simple nozzle
change. Unit 58CLR105 covers input ranges from 70,000 to
105,000 Btuh.
Unit 58CLR120 covers input ranges from
119,000 to 154,000 Btuh. The furnace design is a low- -boy style
for upflow applications where overhead space is limited.
The components of the 58CLR are the finest in the industry. The
unit uses a Riello oil burner with a UTEC fan timer board.
The 58CLR is a standard part of a quality- -built home. This high
efficiency furnace will provide years of quality service to home
builders and homeowners alike.
As with other Carrier furnaces, this model is designed to work as
part of a total home comfort system which includes elements for
cooling, air cleaning, humidification, ventilation, and zoning.
Product Data
58CLR FEATURES/BENEFITS
Riello Oil Burner and UTEC Controls
S
S
Casing
S
S
A06626
Insulation and Soundproofing
S
S
Combustion Products Venting
S
S
S
Adjustable Blower Speed
S
Constant Low- -Speed Blower Switch
S
S
S
Combustion Chamber/Heat Exchanger
S
S
S
Certifications
S
S
1
High quality Riello oil burner allows safe and efficient
combustion of oil.
UTEC ignition control and fan timer board provide
reliable operation and easy connection of thermostat
and accessory wiring.
Made of 18- -gauge painted steel for years of durability.
Cabinet features an insulated enclosure for the burner
and controls.
Unique sound trap along with insulated walls
efficiently capture most combustion noise and vibration
make this unit one of the quietest on the market.
Flue silence baffle ensures quiet operation.
Rear flue outlet.
Unit may be vented using Type L vent material and a
factory- -built metal or masonry chimney.
Unit may also be sidewall vented with an approved
power venter.
4- -speed blower for precise airflow selection of heating
or cooling operation.
Allows continual low- -speed air circulation through the
home to
maximize comfort while maintaining
efficiency.
Air is constantly filtered and stagnant air is avoided.
This option can be controlled by the homeowner.
Composed mainly of stainless and aluminized steel, the
unique
combination
combustion
exchanger
resists
corrosion,
deterioration.
Heat transfer properties make it highly efficient.
All seams are tightly welded for leak- -free operation.
58CLR unit is CSA certified.
The efficiency is GAMA efficiency rating certified.
chamber/heat
overheating,
and

Advertisement

Table of Contents
loading

Summary of Contents for Carrier Low-Boy 58CLR

  • Page 1 Adjustable Blower Speed unit uses a Riello oil burner with a UTEC fan timer board. The 58CLR is a standard part of a quality- -built home. This high 4- -speed blower for precise airflow selection of heating efficiency furnace will provide years of quality service to home or cooling operation.
  • Page 2: Model Number Nomenclature

    LEADS A96369 A96370 A06115 COMBUSTION CHAMBER/ CONTROL CENTER OIL BURNER HEAT EXCHANGER MODEL NUMBER NOMENCLATURE 58CLR Cooling Size Airflow (Nominal 400 CFM per 12,000 Btuh Cooling) Riello Burner 12 --- 1200 CFM Low--- Boy Oil Furnace Series Input Capacity 105 --- 70,000 Btuh with 0.40 gph nozzle 91,000 Btuh with 0.50 gph nozzle...
  • Page 3 A96281 1. Heavy- -duty blower circulates air across the heat 9. Fully insulated internal walls to minimize heat loss. exchanger to transfer heat into the home. 10. High limit control to prevent overtemperature. 2. Access door to air filters and blower. 11.
  • Page 4: Clearance To Combustibles

    CLEARANCE TO COMBUSTIBLES UNIT APPLICATION LOW---BOY Furnace SIDES Supply Plenum and Warm--- Air Duct Within 6 Ft of Furnace BACK Service Clearance Furnace Casing or Plenum Horizontal Warm--- Air Duct Within 6 Ft of Furnace BOTTOM* Horizontally or Below Pipe FLUE PIPE Vertically Above Pipe FRONT...
  • Page 5: Performance Data

    PERFORMANCE DATA UNIT SIZE 105---12 120---20 DIRECT ---DRIVE MOTOR Hp (PSC) MOTOR FULL LOAD AMPS RPM (Nominal) --- SPEEDS 1075--- 4 1075--- 4 BLOWER WHEEL DIAMETER X WIDTH (In.) 10 x 8 12 x 10 FILTER SIZE (In.) --- (Disposable) (2) 12 x 20 x 1 (2) 16 x 20 x 1 AIR DELIVERY - -CFM (WITH FILTERS)
  • Page 6 DIMENSIONS 20" 20" 20" ⁄ ″ VENT CONN 10" 3" A98009 DIMENSIONS (IN.) UNIT DIMENSIONS RETURN SUPPLY FLUE HEIGHT UNIT VENT OPENING OPENING WIDTH DEPTH HEIGHT SIZE CONN 105---12 21--- 1/4 53--- 3/4 31--- 1/2 26--- 1/2 120---20 21--- 1/4 60--- 5/32 34--- 3/4 28--- 11/32...
  • Page 7 RECOVERY MECHANICAL AIR CLEANER AND ZONING VENTILATOR Available in programmable Carrier’s energy or heat recov- Cleans the air of smoke, dirt, By adding moisture to winter ---dry air, and non ---programmable ery ventilators exhaust stale in- and many pollens commonly...
  • Page 8: Typical Installation

    LOW-BOY OIL PIPE FURNACE AIR FLOW A98010 Copyright 2007 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 01/07 Catalog No: 58CLR ---3PD Replaces: 58CLR--- 2PD Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

Table of Contents