Wiring Diagram - KOCOM KIV-212 User's Manual For Operation And Installation

Color hands-free video phone
Table of Contents

Advertisement

Wiring Diagram

Wiring for single house without lobby phone connection
※ ※ Cautions
1. Pin No.1, 2, 7 & 8 in Main Line Port should be connected between main and sub monitor for internal
call and communication.
2. For the connection with KIP-603, please refer to the wiring diagram in multi houses (apartment) in next.
3. In extention with KIP-603 (Audio phone), it is not available to make conversation with front door camera.
4. The DIP switch in sub unit should be set as "0".
※ ※ Cautions
- Door lock connection
Only one door lock should be installed and connected to the monitor for front door open. (single house use)
If 2 door locks are installed in parallel connection, these 2 doors will be open at same time.
- Front door camera connection
Be careful in camera connection to the camera ports. As the camera ports have different 2 call sounds,
if camera 1 is connected to the camera port 1 in main monitor and to the camera port 2 in sub monitor,
main monitor and sub monitor have different 2 call sounds. And camera 1 has 2 different call back tones, too.
- Call sounds : Camera 1 - 'Ding~Dong~' 2 times.
Camera 2 - 'Ddiriri~' 8 times.
Precautions for Wiring
� As incorrect wiring may cause the device' s non-operation
or poor communication quality, please carefully
conduct wiring work.
� When connecting a wiring chord to a terminal, loosen
screw, insert the end of the chord into the bottom part of
screw, and tighten the screw.
� When fixing wiring chord, use stapler not to cause damage
to the chord.
� When using existing wiring, please be cautious not to
cause disconnection and short-circuit.
13
Wiring Diagram
� Wiring for multi houses (apartment) using KLP-C100 series Lobby phone.
- Video phone to Video phone wiring in a house.
※ ※ Cautions
1. Pin No.6 (data line) in Main Line Port is not connected in sub video phone.
2. Pin No.1, 2, 3, 4, 5, 7 & 8 in Main Line Port are used in a form of parallel connection between
main monitor and sub monitor.
3. The DIP switch in sub unit should be set as "0".
※ ※ Cautions
- Door lock connection
Only one door lock should be installed and connected to the monitor for front door open. (single house use)
If 2 door locks are installed in parallel connection, these 2 doors will be open at same time.
- Front door camera connection
Be careful in camera connection to the camera ports. As the camera ports have different 2 call sounds,
if camera 1 is connected to the camera port 1 in main monitor and to the camera port 2 in sub monitor,
main monitor and sub monitor have different 2 call sounds. And camera 1 has 2 different call back tones, too.
- Call sounds : Camera 1 - 'Ding~Dong~' 2 times.
Camera 2 - 'Ddiriri~' 8 times.
14

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kiv-d212Kiv-202Kiv-d202Kc-c60Kc-mc35

Table of Contents