When planning a fireplace insert installation, it's necessary to
determine:
Gas supply piping.
Electrical connections - for optional light kit
MODEL
A
VFLL38FP
43-1/4
35-1/4 11-31/32
NOTE: you must use the standoffs that are supplied with the
fireplace. The standoffs are shipped in a flat-state on top of
the fireplace.
1.
Locate the two steel standoffs on top of the fireplace.
2.
Remove the two screws that secure the standoffs in place;
save the screws.
3.
The standoffs have a perforation located in the middle. Bend
them at the perforation.
Page 8

FIREpLACE DIMENSIONS

E
D
C
A
vF FIREpLACE DIMENSIONS (in inches)
B
C
D
38-1/4
Figure 2
Electrical supply requirements for optional light.
(120V, 60Hz, 1 Amp)
Proper opening size of fireplace required for installation of
the fireplace insert.
F
B
G
E
F
G
41-5/8
11-15/32
1/2
Figure 1
4.
Bend the short tabs on each end in opposite directions. Se-
cure the standoffs to the fireplace top with three screws each
from the hardware bag. There are pilot holes located in the
top of the fireplace for each stand-off. See Figure 2
5.
Use pliers to bend the side standoffs 90 degrees. See Figure
3.
6.
Locate framing bracket package. Install six framing brackets
with two 10 x 1/2 screws (each). See Figures 2 and 3.
K
J
I
H
H
I
J
10-15/16
15/16
21-1/8
Figure 3