ELECTRICAL INSTALLATION
MODEL
345-11
345-12
345-13
Mentioned in title 33 Code of Federal Regulations, Part 183, Subpart I, Section 183.435.b
1. When the appliance is installed in a marine vessel a terminal adequate for a number 8
AWG conductor is provided for use when the vessel has a lightening protection system.
DO NOT USE GROUND LINK (BRIDGE) BETWEEN GROUND AND NEUTRAL.
2. Connect leads from flexible conduit to a junction box conveniently located for service or
inspection.
(4) Four 8 x 1 stainless screws are provided for securing the oven to the cabinet. Counter sunk
mounting holes on the side trims are accessible when the door is open. See mounting diagram
and cut-out dimensions on page 3.
To reduce risk of tipping the appliance, it must be secured by proper installation of
mounting screws (packed with the appliance). If the screws supplied with the appliance
cannot be used, choose an appropriate fastener for the installation requirement.
ELECTRICAL REQUIREMENTS
The branch circuit requirement is as follows:
VOLTAGE
120
240 (3 Wire)
240 (2 Wire)
345 WALL OVEN MOUNTING
WARNING
RATING
BREAKER SIZE
(KW)
1.3
2.6
15 (DUAL POLE)
2.6
15 (DUAL POLE)
MINIMUM*
WIRE SIZE
(AMPS)
15
(AWG)
14
14
14