PERFORMANCE DATA (CONT)
50SZ060
TEMP °F (°C)
OUTDOOR AIR
ENTERING
57
62
CONDENSER
(13.8)
(16.6)
TC
51.1
56.1
75
SHC
51.1
40.5
(23.8)
kW
4.1
4.2
TC
49.4
53.9
85
SHC
49.4
39.5
(29.4)
kW
4.5
4.6
TC
47.5
51.4
95
SHC
47.5
38.4
(35)
kW
5.0
5.1
TC
45.5
48.6
105
SHC
45.5
37.2
(40.5)
kW
5.5
5.6
TC
43.2
45.5
115
SHC
43.2
35.9
(46.6)
kW
6.1
61
TC
40.7
42.1
125
SHC
40.7
34.5
(51.6)
kW
6.6
6.7
See page 16 for cooling notes.
50SZ060
RE-
TURN
CFM
AIR
(Standard
- - 10
°F db
Air)
(- - 23.3)
(°C)
TC
17.8 16.4 22.8 21.0 28.1 25.8 32.3 29.4 34.5 31.3 42.8 37.5 49.2 49.2 56.0 56.0 58.4 58.4 66.4 66.4
1750
kW
3.32
60
TC
17.7 16.3 22.7 20.9 28.1 25.8 32.3 29.4 34.6 31.4 42.9 37.6 49.2 49.2 55.6 55.6 57.8 57.8 65.2 65.2
(15.5)
1875
kW
3.22
TC
18.2 16.8 23.3 21.4 28.6 26.3 32.9 30.0 35.1 31.9 43.5 38.1 49.7 49.7 55.5 55.5 57.6 57.6 64.3 64.3
2000
kW
3.31
TC
16.7 15.4 21.6 19.8 27.1 24.9 31.0 28.3 33.5 30.4 41.8 36.6 51.1 51.1 55.0 55.0 57.7 57.7 66.2 66.2
1750
kW
3.54
70
TC
16.6 15.4 21.5 19.8 27.1 24.9 31.2 28.4 33.5 30.4 41.8 36.7 48.2 48.2 55.1 55.1 57.5 57.5 65.4 65.4
(21.1)
1875
kW
3.45
TC
17.1 15.8 22.1 20.3 27.6 25.4 31.8 29.0 34.1 30.9 42.4 37.2 48.9 48.9 55.4 55.4 57.6 57.6 65.0 65.0
2000
kW
3.54
TC
15.6 14.4 20.3 18.7 25.8 23.7 30.0 27.3 32.2 29.2 40.7 35.6 49.8 49.8 57.1 57.1 59.9 59.9 65.6 65.6
1750
kW
3.76
80
TC
15.4 14.3 20.2 18.6 25.8 23.7 30.0 27.4 32.2 29.2 40.8 35.8 50.0 50.0 54.0 54.0 56.6 56.6 65.2 65.2
(26.6)
1875
kW
3.67
TC
15.9 14.7 20.8 19.1 26.4 24.3 30.6 27.9 33.0 30.0 41.4 36.3 50.8 50.8 54.6 54.6 57.2 57.2 65.1 65.1
2000
kW
3.76
LEGEND
Cap. — Heating Capacity (1000 Btuh) (Includes Indoor ---Fan Motor
Heat)
db
— Dry Bulb
kW
— Total Power Input (Includes Compressor Motor Power Input
Outdoor ---Fan Motor Input, and Indoor ---Fan Motor Input)
rh
— Relative Humidity
COOLING EXTENDED PERFORMANCE TABLE
EVAPORATOR AIR --- CFM/BF
1750 / 0.07
63*
67
72
57
(17.2)
(19.4)
(22.2)
(13.8)
60.7
60.7
66.2
53.5
42.2
42.2
33.4
53.5
4.2
4.2
4.3
4.2
58.3
58.3
64.0
51.7
41.2
41.2
32.6
51.7
4.6
4.6
4.7
4.6
55.8
55.8
61.5
49.8
40.2
40.2
31.8
49.8
5.1
5.1
5.2
5.1
53.0
53.0
58.8
47.6
39.1
39.1
30.8
47.6
5.6
5.6
5.7
5.6
49.9
49.9
55.8
45.3
37.9
37.9
29.8
45.3
6.2
6.2
6.2
6.1
46.5
46.5
52.5
42.7
36.6
36.6
28.7
42.7
6.7
6.7
6.8
6.7
HEATING EXTENDED PERFORMANCE TABLE
AIR TEMPERATURE ENTERING OUTDOOR COIL °F (°C)
0
10
17
(- - 17.7)
(- - 12.2)
(- - 8.3)
3.51
3.68
3.82
3.40
3.56
3.70
3.48
3.63
3.76
3.76
3.99
4.13
3.66
3.86
4.00
3.74
3.93
4.06
4.02
4.29
4.47
3.92
4.17
4.34
4.00
4.24
4.39
1875 / 0.08
Evaporator Air Ewb °F (°C)
62
63*
67
72
(16.6)
(17.2)
(19.4)
(22.2)
57.0
57.4
62.0
67.0
54.2
43.4
45.2
35.0
4.3
4.3
4.3
4.3
54.8
55.2
59.6
65.1
52.9
42.4
44.3
34.5
4.7
4.7
4.7
4.8
52.7
52.6
57.0
62.5
50.9
41.4
43.3
33.6
5.1
5.1
5.2
5.2
50.5
49.8
54.2
59.8
48.7
40.2
42.3
32.7
5.7
5.6
5.7
5.7
48.0
46.6
51.0
56.8
46.3
38.8
41.1
31.8
6.2
6.2
6.2
6.3
45.2
4302
47.6
53.5
43.7
37.4
39.7
30.7
6.8
6.7
6.8
6.9
20
30
40
(- - 6.6)
(- - 1.1)
(4.4)
3.90
4.13
4.30
3.77
3.95
4.12
3.82
3.96
4.14
4.21
4.50
4.74
4.07
4.33
4.50
4.13
4.35
4.52
4.55
4.86
5.16
4.41
4.70
4.95
4.46
4.73
4.94
NOTES:
1.
indicates integrated ratings
2. Integrated capacity is maximum (instantaneous) capacity less the effect
of frost on the outdoor coil and the heat required to defrost it.
16
2000 / 0.09
57
62
63*
67
(13.8)
(16.6)
(17.2)
(19.4)
55.4
58.7
58.5
62.9
55.4
56.7
46.2
48.1
4.3
4.3
4.3
4.4
53.6
56.8
56.1
60.6
53.6
54.8
45.2
47.2
4.7
4.8
4.8
4.8
51.6
54.7
53.6
58.0
51.6
52.8
44.1
46.3
5.2
5.2
5.2
5.3
49.4
52.4
50.7
55.1
49.4
50.6
43.0
45.2
5.7
5.8
5.7
5.8
47.0
49.8
47.6
52.0
47.0
48.1
41.6
44.0
6.2
6.3
6.3
6.3
44.4
47.0
44.1
48.5
44.4
45.4
40.1
42.6
6.8
6.9
6.9
6.9
47
50
(8.3)
(10)
(15.5)
4.48
4.56
4.28
4.36
4.30
4.37
4.88
4.97
4.67
4.75
4.67
4.75
5.37
5.49
5.09
5.18
5.08
5.17
72
(22.2)
67.7
36.6
4.4
65.8
36.2
4.9
63.3
35.4
5.3
60.6
34.5
5.8
57.6
33.6
6.4
54.2
32.5
7.0
60
4.89
4.66
4.63
5.32
5.07
5.05
5.76
5.52
5.49