Carrier 38YCG Product Data page 20

60 hz sizes 018 thru 060
Table of Contents

Advertisement

Detailed cooling capacities* continued
EVAPORATOR
AIR
85
Capacity
MBtuh†
CFM
EWB
Total
Sens‡
38YCG060-32, 34 Outdoor Section With F(A,B)4(A,B)N(F,B)060 Indoor Section
72
63.8
31.9
67
58.2
41.1
1800
63††
54.1
39.8
62
53.2
49.8
57
52.0
52.0
72
64.4
33.1
67
58.8
43.1
2000
63††
54.7
41.7
62
54.0
52.4
57
53.5
53.5
72
64.9
34.2
67
59.3
45.0
2200
63††
55.1
43.5
62
54.8
54.5
57
54.7
54.7
Indoor
Section
Size
CC5A/CD5AA
060
CC5A/CD5AW
060
CE3AA
060
CK3BA
060
CK5A/CK5BA
060
CK5A/CK5BT
060
CK5A/CK5BX
060
F(A,B)4(A,B)N(F,B,C)
060
FB4(A,B)NB
070
FC4(B,C)N(F,B)
060
FC4(B,C)NB
070
FG3AAA
060
FK4(C,D)NB
006
COILS + 58CV(A,X)110-22 VARIABLE-SPEED FURNACE
CC5A/CD5AA
060
CE3AA
060
CK3BA
060
CK5A/CK5BA
060
CK5A/CK5BT
060
NOTE: When the required data fall between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
* Detailed cooling capacities are based on indoor and outdoor unit at same elevation per ARI standard 210/240-94. If additional tubing length and/
or indoor unit is located above outdoor unit, a slight variation in capacity may occur.
† Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
‡ Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct 835
Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S)
of indoor coil air per degree above 80°F (27°C).
** System kW is total of indoor and outdoor unit kilowatts.
†† At TVA rating indoor condition (75°F edb/63°F ewb). All other indoor air temperatures are at 80°F edb.
EWB — Entering Wet Bulb
20
CONDENSER ENTERING AIR TEMPERATURES °F
95
Capacity
Total
Total
MBtuh†
System
System
kW**
Total
Sens‡
kW**
5.67
60.9
30.9
6.17
5.55
55.5
40.0
6.03
5.46
51.5
38.7
5.94
5.44
50.7
48.6
5.93
5.42
50.0
50.0
5.91
5.79
61.5
32.1
6.29
5.67
56.0
42.0
6.15
5.58
52.1
40.6
6.06
5.56
51.6
51.0
6.04
5.55
51.4
51.4
6.04
5.90
62.0
33.2
6.40
5.78
56.5
43.9
6.26
5.69
52.4
42.4
6.17
5.68
52.6
52.6
6.17
5.68
52.5
52.5
6.17
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Capacity
Power
0.96
0.94
0.99
0.96
1.00
0.96
0.96
0.92
0.96
0.92
0.96
0.92
0.99
0.95
1.00
1.00
1.01
1.01
1.00
0.96
1.01
1.01
0.97
0.94
1.00
0.94
0.96
0.92
0.99
0.92
0.98
0.93
0.98
0.93
0.98
0.93
105
Capacity
Capacity
Total
MBtuh†
MBtuh†
System
Total
Sens‡
kW**
Total
57.9
29.9
6.70
54.8
52.6
38.8
6.57
49.8
48.9
37.6
6.47
46.1
48.3
47.3
6.45
45.8
48.0
48.0
6.45
45.8
58.4
31.0
6.82
55.3
53.2
40.9
6.68
50.2
49.3
39.4
6.58
46.6
49.2
49.2
6.58
46.9
49.2
49.2
6.58
46.9
58.9
32.1
6.94
55.6
53.6
42.8
6.79
50.6
49.7
41.2
6.70
46.9
50.3
50.3
6.71
47.9
50.3
50.3
6.71
47.9
Indoor
Section
Size
CK5A/CK5BX
060
COILS + 58CV(A,X)135-22 VARIABLE-SPEED FURNACE
CC5A/CD5AA
060
CC5A/CD5AW
060
CE3AA
060
CK3BA
060
CK5A/CK5BA
060
CK5A/CK5BT
060
CK5A/CK5BX
060
COILS + 58CV(A,X)155-22 VARIABLE-SPEED FURNACE
CC5A/CD5AA
060
CC5A/CD5AW
060
CE3AA
060
CK3BA
060
CK5A/CK5BA
060
CK5A/CK5BT
060
CK5A/CK5BX
060
115
125
Capacity
Total
MBtuh†
System
Sens‡
kW**
Total
Sens‡
28.8
7.29
51.6
27.7
37.7
7.15
46.8
36.6
36.4
7.04
43.2
35.2
45.7
7.03
43.4
43.4
45.8
7.03
43.4
43.4
29.9
7.41
51.9
28.8
39.7
7.26
47.1
38.5
38.3
7.16
43.6
37.0
46.9
7.17
44.5
44.5
46.9
7.17
44.5
44.5
31.0
7.53
52.2
29.9
41.6
7.38
47.4
40.4
40.0
7.27
43.9
38.7
47.9
7.30
45.4
45.4
47.9
7.30
45.4
45.4
Cooling
Capacity
Power
1.00
0.92
0.96
0.92
0.98
0.92
0.99
0.92
0.98
0.93
0.98
0.93
0.98
0.94
1.00
0.92
0.96
0.91
0.98
0.92
0.99
0.91
0.98
0.93
0.98
0.93
0.98
0.93
1.00
0.91
Total
System
kW**
7.93
7.78
7.66
7.67
7.67
8.05
7.89
7.78
7.81
7.81
8.17
8.01
7.89
7.94
7.94