Cancel / Abort Feature (Optional, If Programmed); Bypassing Zones - Hills Series LCD Code Pad User Manual

Lcd code pad
Hide thumbs Also See for Series LCD Code Pad:
Table of Contents

Advertisement

CANCEL / ABORT FEATURE (Optional, if programmed)

The cancel light will flash during an abort delay time. If a code is entered followed
by the [CANCEL] key while this light is flashing, all abortable reports will stop the
communication process. NOTE: The abort feature must be enabled. Entering a
code followed by the [CANCEL] key during or after an alarm report to the central
station will cause the cancel light to come on. It will stay on until the central station
has received the cancel report. NOTE: The cancel feature must be enabled.

BYPASSING ZONES

If you wish to bypass one or more zones, this must be done while the system is in
the disarmed state. If the zone is not known, refer to Procedure #2.
If you know the number of the zone to bypass, use the following:
Procedure #1
Step 1
Press the [BYPASS] key.
Step 2
When the LCD prompts for a code (optional, if programmed), enter your
user code.
Step 3
The bypass light flashes.
Step 4
Enter the zone you wish to bypass. (Example: Press 6
1
1
Step 5
Press the [BYPASS] key again. The zone is now bypassed.
Step 6
Repeat steps 4 and 5 for any other zone(s) that need to be bypassed.
Step 7
Press the [BYPASS] key again OR press # to exit the Bypass Mode.
The bypass light will stop flashing upon exiting the Bypass Mode.
Pressing the • – scroll keys will display all bypassed zones. Press
the # key to exit this viewing mode.