Before asking for a service call please check the following.
These symptoms are part of the normal operation of the unit and do not indicate a fault.
Symptom
At Ignition:
Warm air does not start when the burner
lights.
Smoke or strange smells are produced on
the first trial light up after installation.
Sharp clicking noises at ignition, or when
the unit cuts down on the thermostat, or
goes out.
During combustion:
Clunking noise when the thermostat
operates.
When the unit is turned 'OFF':
Convection fan continues to run after
turning 'OFF'
Other points:
Steam is discharged from the flue terminal.
Heater does not start even when 'ON'
button is pushed and thermostat is on
HIGH.
Timers:
Timers do not operate at set time.
Timer operates for 30 seconds then cuts
out.
Rinnai Australia
TROUBLE SHOOTING
26
Explanation
The fan is started automatically after a short delay.
This is to allow the heat exchanger to warm up,
helping to avoid cold draughts.
This is caused by grease or oil from the
manufacturing process on the heat
exchanger and dust, and will stop after a short time.
This is simply expansion noise from the metal heat
exchanger.
This is the sound of the solenoid gas valves
opening and closing.
This is to remove the residual heat from the heat
exchanger. The fan will stop when the unit cools
down.
High efficiency appliances tend to discharge water
vapour on cold days. This is normal.
Check timer. Timer must be in the "OFF" position
for manual operation.
Room temperature is hotter than 'High' setting.
Timers may either be inactivated or incorrectly
programmed. Repeat programming. Refer to
"OPERATING THE TIMERS" on page 11.
Room temperature may be higher than set
temperature. Adjust temperature upwards if
desired.