MPL11 Woodburning Fireplace
Survey the planned location for the fireplace for overhead plumbing or electrical wires, etc., that
might complicate the installation or endanger persons installing or cleaning the chimney. Avoid
a location where the chimney cap will be near abrupt changes in the roof shape, nearby wall or
embankments, under or near trees or above the roof of a single story wing of a two story building.
Figure 6. All these conditions can cause turbulence or pressure conditions that can cause poor
chimney draft and smoke spillage from the fireplace opening. Elbows may be used to offset the
chimney to avoid obstructions or to locate the chimney cap in a preferred location. Refer to the
sections of this manual pertaining to chimney offsets for instructions on proper elbow usage. Poor
installation or location of the chimney cap and/or components can cause wind blown rain to enter
the chimney.
If the fireplace is to be installed on an outside wall, the surrounding walls (chase) should be insu-
lated. Failure to insulate the fireplace from outside temperatures will cause heat loss through and
around the fireplace.
Single Story installation with attic Space
Chimney Cap
Storm Collar
Flashing
14' Min.
17" Square
Opening in
Joist
Figure 4
Figure 6
8
FP1882
chimney location
8/08
Flue Outlet Height
3' Min. or 2' Above
any Point within 10'
Attic Space
See Table
1 for Roof
Opening Size
Firestop Spacer
(1Z\x" Air space
Clearance to
Combustibles)
Chimney
Sections
2" Min. Air Space
Clearance Between
Combustibles and
Chimney
Preferred
Location
FP2347
single story install
FP1882
Chimney Cap
Storm Collar
(Included with
cap)
Flashing
17" Square Open-
ing in Joist
Max. instal-
lation height
-
86 ft.
Support re-
quired every
35 ft.
17" Square
Opening in
Joist
FP2347
17" Square
Opening in Joist
Poor
Location
Figure 5

iNStaLLatioN PreParatioN

Multiple Story installation
Flue Outlet Height
3 ft. Min. 
Refer to Table
1 for Roof
Opening Size
Firestop
Spacer (2"
Air Space
Clearance to
Combustibles)
2" Clearance to
Combustibles (Min.)
Firestop
Spacer
Firestop
Spacer
FP2348
FP2348
multistory install
Attic Space
Third Floor
Area
Second
Floor Area
First Floor
Area
87D0173