< TUNER SECTION >
1. Clock frequency Check
Settings : • Test point : TP2 (CLK)
Method : Set to AM 1710kHz and check that the test point is
2160kHz ± 45Hz.
2. AM VT Check
Settings : • Test point : TP1 (VT)
Method : Set to AM 1710kHz, 530kHz and check that the test
point is less than 8.5V (1710kHz) and more than
0.6V (530kHz).
3. FM VT Check
Settings : • Test point : TP1 (VT)
Method : Set to FM 87.5MHz, 108.0MHz and check
that the test point is more than 0.5V
(87.5MHz) and less than 8.0V (108.0MHz).
4. AM Tracking Adjustment
Settings : • Test point : TP8(Lch), TP9(Rch)
• Adjustment location :
L951(1/3) ...................................... 1000kHz
Method : Set to AM 1000kHz and adjust L951(1/3) to MAX.
5. FM Tracking Check
Settings : • Test point : TP8(Lch), TP9(Rch)
Method : Set to FM 98.0MHz and check that the test point is
less than 9dBµV.
6. AM IF Adjustment
Settings : • Test point : TP5(Lch), TP6(Rch)
• Adjustment location :
L802 ................................................ 450kHz
7. DC Balance / Mono Distortion Adjustment
Settings : • Test point : TP3, TP4 (DC Balance)
: TP8(Lch), TP9(Rch) (Distortion)
• Adjustment location : L801
• Input level : 60dBµV
Method : Set to FM 98.0MHz and adjust L801 so
that the voltage between TP3 and TP4
becomes 0V ± 0.04V.
Next, check that the distortion is less than
1.3%.
< DECK SECTION >
8. Tape Speed Adjustment (DECK 2)
Settings : • Test tape : TTA–100
• Test point : TP8(Lch), TP9(Rch)
• Adjustment location : SFR1
Method : Play back the test tape and adjust SFR1 so that the
frequency counter reads 3000Hz ± 5Hz and ± 45Hz
(REV) with respect to forward speed.
9. Head Azimuth Adjustment (DECK 1, DECK 2)
Settings : • Test tape : TTA–330
• Test point : TP8(Lch), TP9(Rch)
• Adjustment location : Head azimuth
Method : Play back (FWD) the 8kHz signal of the test tape and
adjust screw so that the output becomes maximum.
Next, perform on REV PLAY mode.
10. PB Frequency Response Check (DECK 1, DECK 2)
Settings : • Test tape : TTA–330
• Test point :TP8(Lch), TP9(Rch)
Method : Play back the 315Hz and 8kHz signals of the test
tape and check that the output ratio of the 8kHz signal
with respect to that of the 315Hz signal is within 5dB.
11. PB Sensitivity Check (DECK 1, DECK 2)
Settings : • Test tape : TTA–200
• Test point : TP8(Lch), TP9(Rch)
Method : Play back the test tape and check that the output level of
the test point is 230mV ± 3dB.
12. REC/PB Frequency Response Adjustment (DECK 2)
Settings : • Test tape : TTA–602
• Test point : TP8(Lch), TP9(Rch)
• Input signal : 1kHz / 10kHz (LINE IN)
• Adjustment location : SFR351 (Lch)
Method : Apply a 1kHz signal and REC mode. Then adjust
OSC attenuator so that the output level at the TP5,
TP6 becomes -20VU. Record and play back the 1kHz
and 10kHz signals and adjust SFRs so that the output of
the 10kHz signals becomes 0dB ± 0.5dB with respect to
that of the 1kHz signal.
13. REC/PB Sensitivity Check (DECK 2)
Settings : • Test tape : TTA–602
• Test point : TP8(Lch), TP9(Rch)
• Input signal : 1kHz (LINE IN)
Method : Apply a 1kHz signal and REC mode. Then adjust
OSC attenuator so that the output level at TP5, TP6
becomes 0VU. Record and play back the 1kHz signals
and check that the output is 0dB ± 3.5dB.
< MICON SECTION >
14. µ-CON OSC Adjustment
Settings : • Test point : TP7 (O-KSCAN)
• Adjustment location : L101
Method : Insert AC plug while pressing TUNER function key.
Adjust L101 so that the frequency at the test point is
208.80Hz ± 0.21Hz.
– 36 –