Configuring the Camera

4.4.2 Control and Status Registers

Control and Status Registers for the Camera
Offset
600h
604h
608h
60Ch
614h
61Ch
62Ch *
630h *
* These registers are defined in version 1.31 of the IIDC specification.
4-8
DRAFT
Name
Cur_V_Frame_Rate
Cur_V_Mode
Cur_V_Format
Iso_Channel / Iso_Speed
Iso_En
Continuous Shot
One_Shot / Multi_Shot
Software_Trigger
Data_Depth
Notes
Default = 0
Default = 0
Default = Format 7
Default Channel =0
Default Speed = S400
Default = 0
Default = 0
Multi_Shot is not supported
Write a 1 to set the trigger.
Self cleared when Trigger Mode = 0
Default = 8
Read only