HouseWarmer HW075DVN-1 Installation Instructions And Owner's Manual

Gravity type direct vent wall furnace

Advertisement

INSTALLER: Leave this manual with the appli-
ance.
CONSUMER: Retain this manual for future ref-
erence.
WARNING: If the information in this manual
is not followed exactly, a fire or explosion may
result, causing property damage, personal in-
jury or loss of life.
Do not store or use any gasoline or other flamma-
ble vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
• If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas sup-
plier.
21091-0-0606

INSTALLATION INSTRUCTIONS

AND OWNER'S MANUAL
GRAVITY TYPE DIRECT VENT
EFFECTIVE DATE
This appliance may be installed in an aftermar-
ket, permanently located, manufactured home
(USA only) or mobile home, where not prohibited
by state or local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gasses, unless a cer-
tified kit is used.
WARNING: If not installed, operated and main-
tained in accordance with the manufacturer's in-
structions, this product could expose you to sub-
stances in fuel or from fuel combustion which can
cause death or serious illness.
DO NOT RETURN THIS PRODUCT TO THE
STORE WHERE YOU PURCHASED IT. IF YOU
ARE MISSING PARTS, OR HAVE ANY PROB-
LEMS, CONTACT EMPIRE COMFORT SYS-
TEMS, INC. AT (877) 459-1583.
WALL FURNACE
MODELS
HW075DV(N,P)-1
HW130DV(N,P)-1
HW180DV(N,P)-1
JUNE 2006
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for HouseWarmer HW075DVN-1

  • Page 1: Installation Instructions

    INSTALLATION INSTRUCTIONS AND OWNER’S MANUAL GRAVITY TYPE DIRECT VENT WALL FURNACE MODELS HW075DV(N,P)-1 HW130DV(N,P)-1 HW180DV(N,P)-1 INSTALLER: Leave this manual with the appli- EFFECTIVE DATE ance. JUNE 2006 CONSUMER: Retain this manual for future ref- erence. This appliance may be installed in an aftermar- WARNING: If the information in this manual ket, permanently located, manufactured home is not followed exactly, a fire or explosion may...
  • Page 2: Table Of Contents

    To Turn Off Gas to the Appliance ................21 Parts List ........................22 Parts View ........................23 Maintenance Instructions .................... 24 Troubleshooting ......................25 How to Order Repair Parts ..................26 HouseWarmer Heating Appliance Limited Warranty ..........26 Notes ..........................27 Page 2 21091-0-0606...
  • Page 3: Gas Specifications

    GAS SPECIFICATIONS MODEL FUEL MAXIMUM INPUT HW075DV 7,500 Btu/hr HW130DV Propane/LP -- Natural gas 13,000 Btu/hr HW180DV 18,000 Btu/hr Natural gas: 3.5" water column pressure MANIFOLD PRESSURE Propane/LP gas: 10.0" water column pressure Gas Inlet 3/8" SUPPLY MINIMUM PRESSURE MAXIMUM PRESSURE Natural Gas 5.0"...
  • Page 4: Unit Dimensions

    UNIT DIMENSIONS 24 5/64” 12 15/16” HW075DV 19 39/64” HW130DV 25 19/32” HW180DV 5 1/32” (HW075DV, HW130DV) 7 1/32” (HW180DV) MAKE SURE THAT APPLIANCE IS SUITABLE FOR THE GAS SUPPLY AVAILABLE: NATURAL GAS OR PROPANE/LP. IMPORTANT SAFETY INFORMATION Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
  • Page 5: Introduction

    INTRODUCTION Always consult your local Building Department regarding regu- The installation must conform with local codes or, in the absence lations, codes or ordinances which apply to the installation of a of local codes, with the National Fuel Gas Code ANSI Z223.1/ NFPA 54* Natural Gas and Propane Installation Code, CSA direct vent wall furnace.
  • Page 6: Requirements For Massachusetts

    REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment 4. INSPECTION. The state or local gas inspector of the installed in every dwelling, building or structure used in side wall horizontally vented gas fueled equipment shall whole or in part for residential purposes, including those not approve the installation unless, upon inspection, owned or operated by the Commonwealth and where the the inspector observes carbon monoxide detectors and...
  • Page 7: Termination Clearances

    TERMINATION CLEARANCES Description US Installations Clearance above grade, veranda, porch, deck, or balcony 12 inches (30 cm) Clearance to window or door that may be open 6 inches (15 cm) for appliance ≤ 10,000 Btuh (3 kW), 9 inches (23 cm) for appliances >...
  • Page 8: Installation And Assembly

    INSTALLATION AND ASSEMBLY WARNING: Any change to this heater or its control can be dangerous. Provide adequate clearances and accessibility for purposes of servicing and proper operation. A manufactured home (USA only) installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 or, when such standard is not applicable, the Standard for Manufactured Home Installations, ANSI Z225.1.
  • Page 9 DIRECT VENTING HORIZONTAL INSTALLATION Once the place for the installation is selected, refer to the figure below for positioning the “B” hole. Be sure the skirting- board does not get in the way. MEASUREMENTS (inches) Model HW180DV HW130DV HW075DV 13.75 10.5 6.75 22.5...
  • Page 10: Installation Of Housewarmer Product

    INSTALLATION OF HOUSEWARMER PRODUCT WARNING: Read the installation instructions thoroughly before cutting or drilling any holes for installation. WARNING: Do not remove any rating plates attached to the unit. INSTALLATION AND ANY REPAIRS TO THIS APPLIANCE MUST BE DONE BY A QUALIFIED SERVICE PERSON.
  • Page 11: Interior Preparation And Installation Of The Back Of The Unit

    INTERIOR PREPARATION AND INSTALLATION OF THE BACK OF THE UNIT Wall Bracket Template Locate the wall bracket template included in your kit and remove the perforated sections. Use painters’ tape to secure the wall bracket template onto the interior wall where the heater will be located. 3-1/2”...
  • Page 12 Use a jigsaw to cut the holes out of the wall and discard the inner circle debris. The wall is now prepared for the installation of the unit. Wall Mounting Using four (4) wood screws, attach the wall mounting bracket to the Bracket wall.
  • Page 13: Exterior Installation Of The Venting

    After the back of the unit is attached to the wall, bring the gas line as Line shown on page 9, or follw the installation template indications. Fol- lowing your city, local and state codes, attach the gas line to the unit. NOTE: The gas line runs THROUGH the wall of the house.
  • Page 14 Air Inlet Tube Slide the air inlet tube over the flue outlet tube and fit into the combustion chamber. See page 10 for cutting air inlet tube to proper length. Insert the air inlet pipe carefully to maintain this element’s shape intact.
  • Page 15: Interior Installation Of The Front Of The Unit

    The two slotted holes in the front housing slide onto the slots of the bracket to fit snugly. Temperature Control Knob Push the temperature control knob onto the temperature control rod. The HouseWarmer unit is now properly installed. 21091-0-0606 Page 15...
  • Page 16: Before Operating The Appliance

    BEFORE OPERATING APPLIANCE WARNING Improper installation, adjustments, alterations, service or Thermostatic maintenance can cause property damage, personal injury or Valve loss of life. Installation and service must be conducted by a Qualified Service Person. Under no circumstances should these heaters be modified. In case of gas leaks, close gas valve and call your Qualified Service Person.
  • Page 17 Do not spray any aerosol near heater when in operation. Do not store these elements near appliance. Do not touch grill. Avoid burning yourself. Avoid blocking air inlet and hot air outlet. Do not place flammable elements on or near the heater. IMPORTANT: Under no circumstances should this appliance be modified.
  • Page 18 WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • Page 19 Connect wire from piezo igniter to igniter (arrow). Light the appliance carefully checking all connections with a soapy water solution to assure no leaks are present. Connection Reassemble appliance making sure lower end lids fit into installed grooves. Place knob in position and push down gently. Note: All references must be considered as if the observer is standing in front of the wall and/or appliance.
  • Page 20: Operating Instructions

    OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result, causing property damage, personal injury, or loss of life. A) This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B) BEFORE LIGHTING, smell all around the appliance area for gas.
  • Page 21: Lighting Instructions

    LIGHTING INSTRUCTIONS 1. STOP! Read the safety information on the side of the heater. 2. Check that gas supply to heater is on. 3. Push in gas control knob slightly and turn clockwise to “OFF” position. Do not force (see below). 4.
  • Page 22: Parts List

    HWA10113 HWA10113 HWA10113 FRONT CABINET HWA31966EM HWA32512EM HWA30828EM BURNER UNIT HWA32561P HWA32530P HWA30868P COMMAND PANEL LOCK HWA10450 HWA10450 HWA10450 NAMEPLATE HOUSEWARMER HWA12834 HWA12834 HWA12834 DISTRIBUTION CHAMBER HWA32490P HWA32513P HWA32536P AIR INLET GASKET HWA12768 HWA12770 HWA12769 FLUE OUTLET GASKET HWA12767 HWA12769...
  • Page 23: Parts View

    PARTS VIEW 21091-0-0606 Page 23...
  • Page 24: Maintenance Instructions

    MAINTENANCE INSTRUCTIONS WARNING: • Prior to any maintenance operation, it will be necessary to close the gas supply. • Only qualified personnel are allowed to operate these appliances without the front cabinet installed. OPERATION FREQUENCY FAULTS TO BE PREVENT- REMARKS External cleaning As required External dirty...
  • Page 25: Troubleshooting

    TROUBLESHOOTING PROBLEM CAUSES SOLUTION Pilot flame does not light up A) Gas supply valve closed A) Open gas supply valve B) Air in gas pipes B) Repeat ignition procedure C) Valve does not work properly C) Place knob on PILOT position and depress fully When ignition knob is released, pilot A) Air remains in gas pipes...
  • Page 26: How To Order Repair Parts

    This manual will help you obtain efficient, dependable service from your HouseWarmer heater, and enables you to obtain repair parts correctly. Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts through the distributor.
  • Page 27: Notes

    NOTES 21091-0-0606 Page 27...
  • Page 28 HOUSEWARMER is a registered trademark of Empire Comfort Systems, Inc. Manufactured for: Empire Comfort Systems, Inc. 918 Freeburg Ave. Belleville, IL 62220 PH: 877-459-1583 FAX: 618-233-7097 or 800-443-8648 Page 28 21091-0-0606...

This manual is also suitable for:

Hw075dvp-1Hw130dvp-1Hw180dvn-1Hw180dvp-1Hw130dvn-1

Table of Contents