INSTALLATION – SOLAR STORAGE TANK
WATER HEATER APPLICATION
This water heater is designed for use in a single family domestic dwelling for the purpose of heating potable
water. Its use in an application other than this may shorten its life.
If this water heater is to be used where an uninterrupted hot water supply is necessary for the application or
business, then there should be redundancy within the hot water system design. This should ensure the
continuity of hot water supply in the event that this water heater was to become inoperable for any reason.
We recommend you provide advice to the system owner about their needs and building backup redundancy
into the hot water supply system.
This water heater is designed to be installed as an electric boosted solar water heater with its booster
heating unit connected to a power supply, however it may be installed with an in-series continuous flow or
storage booster.
If this water heater is installed with an in-series booster, then the electric booster heating unit will not be
connected to a power supply and the references to the electric booster heating unit, thermostat and boosting
controls in these installation instructions will not be applicable to the installation.
Note: AS 3498 requires that a water heater provides the means to inhibit the growth of Legionella bacteria in
potable water. This water heater can satisfy this AS 3498 requirement provided the electric booster is
energised for a sufficient period each day and the electric booster thermostat setting is 60°C or higher.
If this water heater is installed with an in-series continuous flow gas booster, then this requirement of
AS 3498 can be satisfied provided the booster is energised, its preset outlet temperature setting is 70°C or
higher and a remote temperature controller is not used.
If this water heater is installed with an in-series storage booster, then this requirement of AS 3498 can be
satisfied provided the storage booster is energised and its thermostat setting is 60°C or higher.
SOLAR WATER HEATER STORAGE TANK LOCATION
The solar storage tank is designed to be installed on the roof directly coupled to the solar collector(s). The
solar water heater should be installed close to the most frequently used outlet and its position chosen with
safety and service in mind. The solar water heater should be installed with a north facing aspect (refer to
"Solar Collector Location"
on page 27).
Clearance must be allowed for servicing of the solar storage tank.
Make sure the temperature pressure relief valve lever is accessible
and the side cover, thermostat and booster heating unit can be
removed for service. You must be able to read the information on
the rating plate. If possible leave side room of one water heater
length so the anode can be inspected or replaced.
Remember you may have to remove the entire solar storage tank
later for servicing. The solar storage tank must be capable of being
removed without structural alteration to the building or major
alteration to the piping.
For a single water heater installation, follow the
diagrams on
pages
25
to
26. For multiple water heater installations, follow the
instructions on pages
36
and
37.
The solar storage tank must be installed horizontally level. Remember all local authorities have regulations
about putting water heaters into roof spaces.
SAFE TRAY
Where damage to property can occur in the event of the water heater leaking, the water heater must be
installed in a safe tray. Construction, installation and draining of a safe tray must comply with AS/NZS 3500.4
and all local codes and regulatory authority requirements. AS/NZS 3500.4 also has particular requirements
when a safe tray must be installed.