Adjustment
13
Position of the needle plate in relation to the needle
.11
13 - 9
Requirement
Needle plate base 3 should rest on the edge of the bed-plate cutout ( see arrows ). Seen in
the direction of sewing the needle should enter the needle hole in the centre.
3
Fig. 13 - 08
Dismount feeder and insert a new needle.
Loosen screws 1 and 2.
Adjust needle plate base 3 according to the requirements.
Tighten screws 2.
Bring stop plate 4 into contact with needle plate base 3 and tighten screws 1.
2
4
1
2
57-056a
1