Minimum Framing Dimensions - Napoleon GD36PTR Installation And Operating Instructions Manual

Natural gas/propane gas
Table of Contents

Advertisement

38
* BGD36 HORIZONTAL VENT SECTIONS: A minimum of 1" at the bottom and sides and 2" at the top of the
vent pipe on all horizontal runs to combustibles is required. Use fi restop spacer W010-1774 (supplied).
* BGD36 VERTICAL VENT SECTIONS: A minimum of 1" all around the vent pipe on all vertical runs to
combustibles is required except for clearances in appliance enclosures. See "MINIMUM ENCLOSURE
CLEARANCES" section. Use fi restop spacer W500-0096 (not supplied).

6.2.1 MINIMUM FRAMING DIMENSIONS

FOR TOP EXIT APPLICATIONS: DO NOT BUILD INTO THIS AREA. IT MUST BE LEFT CLEAR TO
PROVIDE ADEQUATE CLEARANCE FOR THE VENT. IN THIS 14" WIDE AREA CENTRED ALONG THE
TOP EXIT INSTALLATION
SHOWN
48 3/8"
(TOP EXIT)
39"
(REAR EXIT)
14 1 /2"
Combustion protrusions such as mantels and shelves may occur at or after a minimum distance of 2" away
from the side of the appliance. Thereafter, the depth of any protrusions must be equal to or less than the
distance from the side of the appliance up to a depth of 6", after which no greater clearance than 6" is required.
This can be considered a side wall with no length boundary.
W415-0773 / E / 03.13.12
FRONT OF THE APPLIANCE, NO COMBUSTIBLES ARE ALLOWED.
ENCLOSURE
TOP
14"
MINIMUM
1 1 /2"
FINISHING
MAX
MATERIAL
GAS
INLET
LOCATION
35 3 /4"
3"
5 1 /2"
36 1 /2"
WARNING
!
3 /4"
36
3 1 /2"
MAX
OUTSIDE
CHASE
14 1
/2"
14 1
/2"
1 /2"
36
INSIDE
CHASE
2"
1 /2"
36
PROTRUSION
SIDE
2"
4"
WALL
6"
4"