About Your Water Heater - Rheem 612 Owner's Manual And Installation Instructions

874/876 series continuous flow gas water heater
Table of Contents

Advertisement

WATER HEATER APPLICATION
This water heater is designed for use in a single family domestic dwelling for the purpose of heating potable
water. Its use in an application other than this may shorten its life.
MODEL TYPE
®
The Rheem
continuous flow gas water heater model you have chosen is for outdoor installation only. This
model has an extended manufacturer's warranty (refer to
The water heater has a maximum preset outlet temperature setting of:
874 series
876 series
Notes:
The 876 series water heater is marked "THIS APPLIANCE DELIVERS WATER NOT EXCEEDING 50°C
IN ACCORDANCE WITH AS 3498" on the front panel. This model;
must not be installed as an in-series gas booster to a solar water heater, as water temperature
greater than 50°C can be delivered from the water heater contravening its compliance to AS 3498.
must not be installed with a Water Star water heater as water
temperature greater than 50°C can be delivered from the system.
The 874 series of water heater may be installed as an in-series gas
booster to a solar water heater. For information relating to the function
and operation of the solar water heater, refer to the Owner's Guide
and Installation Instructions supplied with the solar water heater.
When installed as an in-series gas booster to a solar water heater, the
874 series water heater:
can deliver water at temperatures up to 70°C to 80°C for a
Premier Loline and Loline pumped system and a Hiline
thermosiphon system and possibly higher temperatures from a
Premier Hiline thermosiphon system.
during periods of low solar energy gain, will boost the water
temperature automatically to its preset outlet temperature setting.
MAINS PRESSURE
The water heater is designed for direct connection to the mains water supply. If the mains supply pressure in
your area exceeds that
should be greater than 140 kPa for the rated flow and performance to be achieved.
WATER HEATER OPERATION
The water heater operates automatically, heating water as it passes through the water heater. When a hot
tap is opened, the gas burners ignite to provide immediate heating of the water. The heat produced by the
burner is transferred to the water through the heat exchanger. The water is heated to a constant temperature
by the automatic adjustment of the gas supply to the burner to suit the water flow rate (refer to
Control"
on pages 11 to 40). The gas burners extinguish when the hot tap is closed.
Automatic safety controls are fitted to the water heater to provide safe and efficient operation.
REDUCED HOT WATER FLOW WHEN HEAT EXCHANGER IS COLD
At a cold start-up, i.e. when the water heater has not operated for some time (which is most often first thing
in the morning), the initial flow of hot water may be reduced for a period of 5-10 seconds while the heat
exchanger warms up. This is both an energy and water saving feature of this water heater. Once the
heat exchanger has warmed up the hot water flow will increase and remain at normal flow levels. This
feature will only occur at a cold start-up and not when the heat exchanger is already warm from a recent use
of hot water.

ABOUT YOUR WATER HEATER

70°C
48°C
shown on page
47, a pressure limiting valve must be fitted. The supply pressure
the Rheem warranty
4
on page 83).
"Temperature