Item
Condition
11. DTMF
1) Set test mode
deviation
Select "n DTMF" in tuning mode. Deviation
Deviation meter filter
LPF : 15kHz
HPF : OFF
PTT : ON
2) "s DTMF"
PTT : ON
3) "w DTMF"
PTT : ON
12. FFSK
1) Set test mode
deviation
Select "n FFSK" in tuning mode.
Deviation meter filter
LPF : 15kHz
HPF : OFF
PTT : ON
2) "s FFSK"
PTT : ON
3) "w FFSK"
PTT : ON
13. TONE
1) Set test mode
deviation
Select "n TONE" in tuning mode.
Deviation meter filter
LPF : 15kHz
HPF : OFF
PTT : ON
2) "s TONE"
PTT : ON
3) "w TONE"
PTT : ON
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power meter Rear
ANT
panel
meter
Oscilloscope
AF VTVM Front
MIC
AG
panel
Adjustment
Parts
Method
± 0.2kHz (Wide/Semi-wide)
3.0kHz (Wide)
± 0.1kHz (Narrow)
2.4kHz (Semi-wide)
1.5kHz (Narrow)
± 0.1kHz
3.0kHz (Wide)
2.4kHz (Semi-wide)
(Wide/Semi-wide/Narrow)
1.5kHz (Narrow)
± 0.1kHz
3.0kHz (Wide)
2.4kHz (Semi-wide)
(Wide/Semi-wide/Narrow)
1.5kHz (Narrow)
TK-780
Specifications/Remarks
53