Kenwood TK-780 Service Manual page 49

Hide thumbs Also See for TK-780:
Table of Contents

Advertisement

Receiver Section
Item
Condition
1. Discriminator 1) Set test mode
CH : CH1 - Sig1
SSG output : –53dBm
AF : 1.4V/4Ω
2. Sensitivity
1) Set test mode
Select "SENS" in tuning mode.
"L SENS"
SSG freq' : 146.050MHz
SSG output : –118dBm/0.31µV meter
SSG MOD : 1.5kHz
AF output : 1V/4Ω
2) "C SENS"
SSG freq' : 160.050MHz
3) "H SENS"
SSG freq' : 173.950MHz
3. Squelch
1) Set test mode
Select "nL SQL" in tuning mode.
SSG freq' : 146.050MHz
SSG output : Sensitivity
value of 12dB SINAD.
SSG MOD : 1.5kHz (Narrow)
2) "nC SQL"
SSG freq' : 160.050MHz
3) "nH SQL"
SSG freq' : 173.950MHz
4) "sL SQL", "sC SQL", "sH SQL"
SSG freq' : Same as
narrow adjustment.
SSG output : Sensitivity
value of 12dB SINAD.
SSG MOD : 2.4kHz (Semi-wide)
5) "wL SQL", "wC SQL", "wH SQL"
SSG freq' : Same as
narrow adjustment.
SSG output : Sensitivity
value of 12dB SINAD.
SSG MOD : 3.0kHz (Wide)
4. RSSI (Low)
1) Set test mode
Select "nL LRSI" in tuning mode.
SSG freq' : 146.050MHz
SSG output : Sensitivity
value of 12dB SINAD.
SSG MOD : 1.5kHz (Narrow)
2) "nC LRSI"
SSG freq' : 160.050MHz
3) "nH LRSI"
SSG freq' : 173.950MHz
4) "sL LRSI", "sC LRSI", "sH LRSI"
SSG freq' : Same as
narrow adjustment.
SSG output : Sensitivity
value of 12dB SINAD.
SSG MOD : 2.4kHz (Semi-wide)
5) "wL LRSI", "wC LRSI", "wH LRSI"
SSG freq' : Same as
narrow adjustment.
SSG output : Sensitivity
value of 12dB SINAD.
SSG MOD : 3.0kHz (Wide)
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
SSG
Rear
ANT
TX-RX L6
panel
(A/2)
AF VTVM
ACC
Oscilloscope
(EXT.SP)
SSG
ANT
AF VTVM
ACC
Distortion
(EXT.SP)
Oscilloscope
AG
Adjustment
Parts
Method
AF output voltage
maximum.
Adjust for
maximum SINAD.
Adjust for
maximum SINAD.
Adjust for
maximum SINAD.
Squelch must be
closed once.
Then adjust for
squelch open point.
Writing values only.
TK-780
Specifications/Remarks
49

Hide quick links:

Advertisement

Table of Contents
loading