Troubleshooting - Waterco HEAT PUMP SWIMMING POOL HEATERS Owner's Manual

Heat pump swimming pool heaters
Table of Contents

Advertisement

How To Protect Your Pool Heater
- Verify that the installation was done according
This Flow Chart will teach you the
steps t o follow to p rotect y our heater
as well as your family by maintaining a
corrosion free pool.
FIRST TIME OR SPRING STARTUP
- Hook up pool water piping but do not hook
VERIFY & BALANCE POOL CHEMICALS
HEATER
HEATER
No
IN
IN
OUT
OUT
OPEN
CLOSED
Water directed
Water goes to
to Pool
heater
- Verify Chlorine or Bromine level every 2-3 da ys.
- Verify PH level once a we ek.
IMPORTANT
- Verify Alkalinity level every 3-4 weeks (More often if you ow n
When heating is not required for
an Automatic Chlorine or Bromine Feeder.) (Above tests can
less than a week you MUST leave the
easily be done by yourself with a do it yourself kit).
Bypass valves open
- Verify Hardness and Total Dissolved Solids (TDS) once a
(See Fig.1) to let the water circulate
month (Above tests must be done by your dealer).
in the unit. If the heat exchanger
is deprived of water circulation
for more than 24 hours, high
chlorine gas could cause excessive
corrosion.
WATER QUALITY STANDARDS
TO STRICTLY ADHERE TO
PH
7.4 to 7.8
CHLORINE CONCENTRATION
1.0 to 4.0 PPM
TOTAL ALKALINITY
100 to 120 PPM
TOTAL DISSOLVED SOLIDS
below 1800 Reg. Pool
below 3500 Salt Pool
CALCIUM HARDNESS
200 to 300
INSTALLATION
to owners' manual instructions.
up to the Heater yet.
POOL CHEMICALS OK?
Yes
HOOK UP WATER PIPING TO HEATER
SET REQUIRED WATER
TEMPERATURE ON TOUCH PAD
IMPORTANT FOR THE HEALTH OF YOUR FAMILY AND
FOR YOUR POOL HEATER
No
HEATING WILL NOT BE REQUIRED
FOR MORE THAN A WEEK?
Yes
Shut Bypass valves and disconnect water
lines to drain the HEATER.
Yes
HEATING NEEDED?
No
No
IS IT POOL CLOSING
TIME?
Yes
CLOSE POOL AND WINTERISE
THE HEATER

TROUBLESHOOTING

The Pool Heater Is Not Running Or Stops Less Than 2 Minutes After
Starting Up
Heat pump control set to low. Raise temperature set point.
Desired water temperature is reached. Unit will automatically re-start when the water temperature
goes below the set point.
Main breaker is tripped. Reset it.
Pool pump is not running. Turn the pool pump on.
Filter is dirty restricting the water flow. Backwash and clean filter.
The Compressor Is Running But The Fan Is Not
If the unit was just installed and the compressor starts before you have programmed the desired temperature,
it is possible that the electrical hookup was made on the wrong side of the contactor (relay). Contact your
electrician.
The fan motor may be defective. Contact Waterco's service dept.
The Fan Is Running But Not The Compressor
The unit is in its 3 or 5 minutes time delay protection mode.
The unit is on defrost. The compressor will start again automatically a few minutes.
There Is Water Around The Unit
While your Watero pool heater is in the heating mode, a large quantity of warm and humid air passes over the
evaporator and causes condensation.
It is normal to see condensation dripping under the heater.
To verify that the water is really a water leak you will need to stop the heater and leave the pool pump
running for over 5 hours. If water is still coming out of your heater after this period you should call Waterco
for service.