Gas Appliance Installation - MHSC SB50HB Installation, Operation And Maintenance Manual

Table of Contents

Advertisement

SB50HB Series Woodburning Fireplace
7. Pack the insulation removed in step 4 around the pipe to prevent air flowing through the tube either
into or out of the firebox.
8. Be sure the gas is turned off at the appliance, then turn the gas on at the shut-off valve and test the
gas line connections for leaks with soapy water solution or a liquid leak detector. DO NOT USE A
MATCH OR OTHER FLAME SOURCE TO CHECK FOR GAS LEAKS. If a gas leak is detected,
turn the gas off immediately and fix the leak.
9. Proceed with testing the appliance for leaks and adjusting it as required by the manufacturer
instructions.
Figure 30
gas Line plumbing detail
Outer Fireplace Wrap
Inner Fireplace Wrap
Side Brick
Hearth Brick
Gas Line Access Tube
CauTION: When using a gas appli-
ance, the fireplace damper must be
set in fully open position.
appLyINg deCOraTIve TrIM TO THe FIrepLaCe
Do not allow the trim materials to extend closer than 3/8 inch to the vertical edges of the firebox opening
if you plan to equip the fireplace with glass doors.
The face of your fireplace may be left exposed or trimmed with any noncombustible material such as
brick, stone or marble. If a trim is installed, be sure it is fastened snugly to the face of the fireplace. A
crack between the material and the face of the fireplace could pose a fire hazard and impair the proper
operation of the fireplace. Blocking the fireplace with framing and attaching the base to the supporting
floor will further reduce the possibility of such a crack developing.
Wall ties should be fastened to the face of the fireplace with sheet metal screws and placed in the mortar
joints of masonry trim.
Combustible material must not be installed below the top spacers of the fireplace or overlap the sides
of the fireplace face. Seal the face of the fireplace to the surrounding wall with non-combustible caulk
or trim materials to prevent cold air leakage around the fireplace.
The trim should not block or restrict in any way the flow of air into the side air inlets in the face of the
fireplace.
Be sure to provide the required floor protection as described in a preceding section of this manual.
Combustible mantels and trim must be installed in accordance with the National Fire Protection Association
- ANSI NFPA 11 Standard - Section 7-.3.3.
8
Maintain 1/" Minimum Air Space
Clearance to Combustibles for
Gas Line Out to 4" From Side of
the Fireplace
Combustible Materials May Be Lo-
cated at Zero Clearance to Gas Line
Beyond 4" From Fireplace Side.
Repack Insulation Around
Gas Line Where it Passes
Through Gas Line Access
Tube for Proper Seal

gaS appLIaNCe INSTaLLaTION

Back Brick
Knockout
Side Brick
FP3
87D0058