Technical Support - Maretron WSO100 User Manual

Ultrasonic wind / weather station
Table of Contents

Advertisement

WSO100 User's Manual
Electrical
Parameter
Operating Voltage
Power Consumption
Load Equivalence Number (LEN)
Reverse Battery Protection
Load Dump Protection
Mechanical
Parameter
Size
Weight
Mounting
Environmental
Parameter
IEC 60945 Classification
Degree of Protection
Operating Temperature
Storage Temperature
Relative Humidity
Vibration
Rain and Spray
Solar Radiation
Corrosion (Salt Mist)
Electromagnetic Emission
Electromagnetic Immunity
Safety Precautions

7 Technical Support

If you require technical support for Maretron products, you can reach us in one of the following
ways:
Page 10
9 to 16 Volts
4.25" Diameter x 3.45" Tall
(108mm Dia. x 88mm Tall)
10 oz. (283 g)
2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s
12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8
Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10
4 times 7days @ 40°C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12
Conducted and Radiated Emission per IEC 60945-9
Conducted, Radiated, Supply, and ESD per IEC 60945-10
Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12
Telephone:
Fax:
E-mail:
World Wide Web:
Mail:
Value
DC Voltage
<150mA
Average Current Drain
3
NMEA 2000
Yes
Indefinitely
Yes
Energy Rated per SAE J1113
Value
Including Mounting Bracket
Including Mounting Bracket
Pole
Fits 1"-14 Standard Marine Mount
Value
Exposed
IP67
-25°C to 55°C
-40°C to 70°C
93%RH @40° per IEC60945-8.2
1-866-550-9100
1-602-861-1777
support@maretron.com
http://www.maretron.com
Maretron, LLC
Attn: Technical Support
rd
9034 N. 23
Ave Suite 13
Phoenix, AZ 85021 USA
Comment
®
Spec. (1LEN = 50 mA)
Comment
2
per IEC 60945-8.7
Revision 1.2

Advertisement

Table of Contents
loading

Table of Contents