The remote interface connector, on the cameras rear panel, is
specified as a low-profile RJ-11 modular connector. The connector
is a 6-position model, but only the center four positions are
populated with contacts. It will mate with either the 4-position or 6-
position cable plugs. This type of connector typically requires
special assembly tools; complete cable assemblies are available from
suppliers such as Digi-Key:
DALSA provides serial cables in 3 lengths: 10', 20' and 50'. Part number CL-31-00004-xx (where xx
refers to the cable length in feet).

2.7 TTL Trigger Input and Output

Connector

The camera uses an SMA connector (labeled TRIGGER IN) to allow the user to
provide a standard TTL signal to control camera integration and readout. The input is
high impedance (>10K) allowing the user to terminate at the SMA input as needed.
The camera has another SMA connector (TRIGGER OUT) that provides a standard
TTL output which is high whenever the camera is integrating.

2.8 Integration Time

The minimum integration time (or shutter time) is 5 µs. As with any full frame
imager, the camera will continue to integrate during read out unless externally
shuttered or strobed.
DALSA
Figure 5. Trigger Timing Description
TTL Trigger Input
Integration
Serial Cable Source
Digi-Key
701 Brooks Ave. South
Thief River Falls, MN 56701
1-800-344-4539
cable part number:
H2643-14-ND (14 feet)
Min. 5 µs
1.5 us
+/- 0.5