Fluke 77 Calibration Information Manual page 13

Series iv
Hide thumbs Also See for 77:
Table of Contents

Advertisement

Steps
Test
(Switch Position)
18
19
L
20
DC Volts
21
22
E
23
DC Millivolts
24
E
25
Capacitance
G
26
[1]
Diode Test
27
F
28
AC Milliamps
29
?
30
AC Amps
31
I
m
32
DC Milliamps
33
A
34
1
DC Amps
35
1. Press the YELLOW button to access this function.
2. Does not include test lead resistance.
Table 2. Performance Tests (cont)
5500 Output
5 V
300 V
1000 V
-1000 V
30 mV
-300 mV
600 mV
Apply 900 nF
[1]
0.5 mA 45 Hz
50 mA 1 kHz
400 mA 1 kHz
4.0 A 45 Hz
9.0 A 1 kHz
3 mA, 0 Hz
50 mA
[1]
-400 mA
4.0 A
-9.0 A
Digital Multimeter
Performance Tests
Meter Response
Lower Limit
4.984 V dc
5.016 V dc
299.0 V dc
301.0 V dc
996 V dc
1004 V dc
-1004 V dc
-996 V dc
29.8 mV dc
30.2 mV dc
-301.0 mV dc
-299.0 mV dc
598.1 mV dc
601.9 mV dc
887 nF
913 nF
0.47 mA ac
0.53 mA ac
48.73 mA ac
51.27 mA ac
389.8 mA ac
410.2 mA ac
3.898 A ac
4.102 A ac
8.75 A ac
9.25 A ac
2.93 mA dc
3.07 mA dc
49.23 mA dc
50.77 mA dc
−406.2 mA dc
−393.8 mA dc
3.938 A dc
4.062 A dc
−9.16 A dc
−8.84 A dc
Upper Limit
13