Available languages

A13
Route wires through the strain relief.
A14
Fan Motor
Light
*Option Fan & Main Light Together
A15
G
Install the wiring cover plate. Make sure all
wiring connections are inside the box or under
the wiring cover plate.
6
Black
2 Pin
White
White
3 Pin
Black
Light
*Option
Connect wires as shown.
E
Ground
Green
A
Bare Copper
Black
Main Switch 1 (AC In)
White
Black
Switch 2 (AC In)
0 A16
Connect 4" duct and vent to the outside. Tape joints.
If ducting does not fit securely, an adapter may need
to be purchased.