Air Duct Assembly; Door Switch - GE DBVH512 Technical Service Manual

Hide thumbs Also See for DBVH512:
Table of Contents

Advertisement

Air Duct Assembly

The air duct assembly houses the lint fi lter, drum
seal, and the 2 sensor rods. It is located on the back
side of the front panel.
To remove the air duct assembly:
1.
Remove the top, control, and front panels. (See
Top Panel, Control Panel and Front Panel.)
2.
Remove the drum slide assembly. (See Drum
Slide Assembly.)
3.
Remove the single Phillips-head screw that
attaches the sensor ground wire to the cabinet.
Sensor Ground Wire
4.
Remove the 2 Phillips-head screws that attach
the air duct assembly to the front panel.
Note:
The 2 sensor rods in the air duct assembly are
not replaceable. To replace the sensor rods,
replace the air duct assembly.
The drum seal can be replaced by extracting the
seal from the channel located on the air duct
assembly.

Door Switch

The door switch is fastened to the front panel
by 2 locking tabs and is common to all dryer
functions. When the dryer door is closed, the switch
will complete the motor circuit, allowing dryer
operation. When the door is open, the switch will
open the motor circuit, interrupting dryer operation.
Opening the dryer door will also cause the door
switch to close the drum light circuit, allowing the
drum light to be energized.
Specifi c failures associated with the door switch can
initiate error codes E03 and E05. (See
.)
Mode